Artificial Intelligence Enabled Fully Automated CMR Function Quantification for Optimized Risk Stratification in Patients Undergoing Transcatheter Aortic Valve Replacement

Author:

Evertz Ruben12ORCID,Lange Torben12ORCID,Backhaus Sören J.12ORCID,Schulz Alexander12,Beuthner Bo Eric12,Topci Rodi12ORCID,Toischer Karl12,Puls Miriam12,Kowallick Johannes T.23,Hasenfuß Gerd12,Schuster Andreas12ORCID

Affiliation:

1. University Medical Center Göttingen (UMG), Department of Cardiology and Pneumology, Göttingen, Germany

2. German Center for Cardiovascular Research (DZHK), Partner Site Göttingen, Göttingen, Germany

3. University Medical Center Göttingen (UMG), Department of Diagnostic & Interventional Radiology, Göttingen, Germany

Abstract

Background. Cardiovascular magnetic resonance imaging is considered the reference standard for assessing cardiac morphology and function and has demonstrated prognostic utility in patients undergoing transcatheter aortic valve replacement (TAVR). Novel fully automated analyses may facilitate data analyses but have not yet been compared against conventional manual data acquisition in patients with severe aortic stenosis (AS). Methods. Fully automated and manual biventricular assessments were performed in 139 AS patients scheduled for TAVR using commercially available software (suiteHEART®, Neosoft; QMass®, Medis Medical Imaging Systems). Volumetric assessment included left ventricular (LV) mass, LV/right ventricular (RV) end-diastolic/end-systolic volume, LV/RV stroke volume, and LV/RV ejection fraction (EF). Results of fully automated and manual analyses were compared. Regression analyses and receiver operator characteristics including area under the curve (AUC) calculation for prediction of the primary study endpoint cardiovascular (CV) death were performed. Results. Fully automated and manual assessment of LVEF revealed similar prediction of CV mortality in univariable (manual: hazard ratio (HR) 0.970 (95% CI 0.943–0.997) p = 0.032 ; automated: HR 0.967 (95% CI 0.939–0.995) p = 0.022 ) and multivariable analyses (model 1: (including significant univariable parameters) manual: HR 0.968 (95% CI 0.938–0.999) p = 0.043 ; automated: HR 0.963 [95% CI 0.933–0.995] p = 0.024 ; model 2: (including CV risk factors) manual: HR 0.962 (95% CI 0.920–0.996) p = 0.027 ; automated: HR 0.954 (95% CI 0.920–0.989) p = 0.011 ). There were no differences in AUC (LVEF fully automated: 0.686; manual: 0.661; p = 0.21 ). Absolute values of LV volumes differed significantly between automated and manual approaches ( p < 0.001 for all). Fully automated quantification resulted in a time saving of 10 minutes per patient. Conclusion. Fully automated biventricular volumetric assessments enable efficient and equal risk prediction compared to conventional manual approaches. In addition to significant time saving, this may provide the tools for optimized clinical management and stratification of patients with severe AS undergoing TAVR.

Publisher

Hindawi Limited

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3