Labelling of 90Y- and 177Lu-DOTA-Bioconjugates for Targeted Radionuclide Therapy: A Comparison among Manual, Semiautomated, and Fully Automated Synthesis

Author:

Iori Michele1,Capponi Pier C.1,Rubagotti Sara1,Esposizione Luca Rosario1,Seemann Johanna2,Pitzschler Riccardo2,Dreger Thorsten2,Formisano Debora3,Grassi Elisa4ORCID,Fioroni Federica4,Versari Annibale1,Asti Mattia1ORCID

Affiliation:

1. Nuclear Medicine Unit, Oncology and Advanced Technologies Department, Arcispedale Santa Maria Nuova-IRCCS, 42123 Reggio Emilia, Italy

2. Eckert & Ziegler Eurotope GmbH, Robert-Roessle-Strasse 10, 13125 Berlin, Germany

3. Department of Infrastructure Research and Statistics, Arcispedale Santa Maria Nuova-IRCCS, Reggio Emilia, Italy

4. Health Physic Unit, Oncology and Advanced Technologies Department, Arcispedale Santa Maria Nuova-IRCCS, 42123 Reggio Emilia, Italy

Abstract

In spite of the hazard due to the radiation exposure, preparation of 90Y- and 177Lu-labelled radiopharmaceuticals is still mainly performed using manual procedures. In the present study the performance of a commercial automatic synthesizer based on disposable cassettes for the labelling of 177Lu- and 90Y-DOTA-conjugated biomolecules (namely, DOTATOC and PSMA-617) was evaluated and compared to a manual and a semiautomated approach. The dose exposure of the operators was evaluated as well. More than 300 clinical preparations of both 90Y- and 177Lu-labelled radiopharmaceuticals have been performed using the three different methods. The mean radiochemical yields for 90Y-DOTATOC were 96.2±4.9%, 90.3±5.6%, and 82.0±8.4%, while for 177Lu-DOTATOC they were 98.3%  ± 0.6, 90.8%  ± 8.3, and 83.1±5.7% when manual, semiautomated, and automated approaches were used, respectively. The mean doses on the whole hands for yttrium-90 preparations were 0.15±0.4 mSv/GBq, 0.04±0.1 mSv/GBq, and 0.11±0.3 mSv/GBq for manual, semiautomated, and automated synthesis, respectively, and for lutetium-177 preparations, they were 0.02±0.008 mSv/GBq, 0.01±0.03 mSv/GBq, and 0.01±0.02 mSv/GBq, respectively. In conclusion, the automated approach guaranteed reliable and reproducible preparations of pharmaceutical grade therapeutic radiopharmaceuticals in a decent RCY. The radiation exposure of the operators remained comparable to the manual approach mainly due to the fact that a dedicated shielding was still not available for the system.