Affiliation:
1. Augusta University Medical Center, 1120 15th Street, Augusta, GA 30912, USA
Abstract
Leadless pacing systems have revolutionized the field of electrophysiology given its low complication rates and almost non-existent rate of infections compared with traditional pacemakers. These devices boast resistance to infections given its unique features; however, as described in this report, device-related infection from these leadless devices is still possible. In patients with leadless pacing system that is persistently bacteremic in the future, evaluation of the device with transesophageal echocardiogram or intracardiac echocardiography should be performed, and if vegetation is noted on the device, device extraction should highly be considered, along with empiric intravenous antibiotics. Lastly, new leadless device should not be re-implanted within 2 weeks of the removal of the infected device to prevent seeding of the new device.
Subject
Cardiology and Cardiovascular Medicine
Cited by
4 articles.
订阅此论文施引文献