Magnetic Resonance Imaging Image Segmentation under Edge Detection Intelligent Algorithm in Diagnosis of Surgical Wrist Joint Injuries

Author:

Li Zhongyi1ORCID,Ji Xi2ORCID

Affiliation:

1. Department of Second Hand Surgery, Affiliated Central Hospital of Shenyang Medical College, Shenyang 110000, Liaoning, China

2. Department of Foot and Ankle Surgery, Affiliated Central Hospital of Shenyang Medical College, Shenyang 110000, Liaoning, China

Abstract

Background. Wrist joint injury refers to the injury of the wrist joint caused by excessive stretching of the ligaments and joint capsules around the joint caused by indirect violence. The tissue structure of the wrist joint is complex, and the clinical diagnosis effect is poor. Methods. The purpose of this study was to improve the diagnostic accuracy of wrist joint injuries and provide evidence for imaging analysis and automatic diagnosis of lesions in patients with wrist joint injuries. The Canny algorithm was adopted to extract the edge features of the patient’s magnetic resonance imaging (MRI) image, and the particle swarm optimization-support vector machine (PSO-SVM) algorithm was applied to segment the lesion. The image processing effect of the algorithm was evaluated by taking peak signal to noise ratio (PSNR), mean square error (MSE), figure of merit (FOM), and structural similarity (SSIM) as indicators. The accuracy, sensitivity, specificity, and Dice similarity coefficient of the algorithm were analyzed to evaluate the diagnostic accuracy in WJI. Results. Compared with the Gradient Vector Flo (GVF) algorithm and the Elastic Automatic Region Growing (ERG) algorithm, the edge stability of the PSO-SVM algorithm was stable above 0.9. After the quality of images processed using different algorithms was analyzed, it was found that the PSNR of the PSO-SVM algorithm was 26.891 ± 5.331 dB, the MSE was 0.0014 ± 0.0003, the FOM was 0.8832 ± 0.0957, and the SSIM was 0.9032 ± 0.0807. The four indicators were all much better than those of the GVF algorithm and the EARG algorithm, showing statistically obvious differences ( P  < 0.05). Analysis on diagnostic accuracy of different algorithms for WJI suggested that the diagnostic accuracy of the PSO-SVM algorithm was 0.9413, the sensitivity was 0.9129, the specificity was 0.9088, and the Dice similarity coefficient was 0.8715. The four indicators all showed statistically great difference compared with those of the GVF algorithm and the EARG algorithm ( P  < 0.05). Conclusions. The PSO-SVM algorithm showed excellent edge detection performance and higher accuracy in the diagnosis of WJI, which can assist clinicians in the clinical auxiliary diagnosis of WJI.

Publisher

Hindawi Limited

Subject

Radiology, Nuclear Medicine and imaging

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3