Affiliation:
1. School of Resource and Environmental Science, Wuhan University, 129 Luoyu Road, Wuhan 430079, Hubei Province, China
Abstract
The correct urban building layout is an important influencing factor in urban ventilation, and the heat island effect has become an important factor affecting the quality of urban life. Optimization of the urban building layout can play a role in mitigating the heat island effect. The traditional ventilation corridor analysis method, based on a least-cost path analysis, can only generate a few main ventilation corridors. It is difficult to obtain global ventilation results covering the whole study area using this method of analysis. On the basis of urban morphology and a least-cost path analysis, this study proposes a “least cumulative ventilation cost” method for analyzing urban ventilation. Taking Wuhan downtown as a research area, the urban ventilation environment under different wind directions and seasons was analyzed. This method can effectively express the ventilation conditions throughout the whole study area and can simultaneously express the quality of the generated corridors effectively. The results show that Wuhan has three levels of ventilation corridor. Moreover, the ventilation conditions in Wuchang (Wuchang, Qingshan, and Hongshan) are better than those in Hankou (Qiaokou, Jianghan, and Jiang’an).
Funder
National Key Research and Development Program of China
Subject
Multidisciplinary,General Computer Science
Cited by
14 articles.