Background. The aim of this study was to investigate the application of computer-aided design and 3D printing technology for percutaneous fixation of femoral neck fractures using cannulated compression screws. Methods. Using computed tomography data, an individualized proximal femur model was created with a 3D printer. The reduction of the femoral neck fracture and the placement of the cannulated compression screws were simulated on a computer. A 3D printing guide plate was designed to match the proximal femur. After demonstrating the feasibility of the 3D model before the surgical procedure, the guide needles and cannulated compression screws were inserted with the aid of the 3D-printed guide plate. Results. During the procedure, the 3D-printed guide plate for each patient matched the bone markers of the proximal femur. With the aid of the 3D-printed guide plate, three cannulated compression screws were accurately inserted into the femoral neck to treat femoral neck fractures. After screw placement, intraoperative X-ray examination showed results that were consistent with the preoperative design. The time taken to complete the procedure in the guide plate group was 35.3 ± 2.1 min , the intraoperative blood loss was 6.3 ± 2.8 mL , and X-ray fluoroscopy was only performed 9.1 ± 3.5 times. Postoperative radiographs showed adequate reduction of the femoral neck fractures. The entry point, entry direction, and length of the three cannulated compression screws were consistent with the preoperative design, and the screws did not penetrate the bone cortex. Conclusion. Using computer-aided design and 3D printing technology, personalized and accurate placement of cannulated compression screws can be realized for the treatment of femoral neck fractures. This technique can shorten the time required for the procedure and reduce damage to the femoral neck cortex, intraoperative bleeding, and the exposure of patients and healthcare staff to radiation.

Funder

Key Project of Hunan Provincial Science and Technology Innovation

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3