Comparison of the Accuracy of Four Malaria Diagnostic Methods in a High Transmission Setting in Coastal Cameroon

Author:

Moyeh Marcel N.123ORCID,Ali Innocent M.24ORCID,Njimoh Dieudonné L.13ORCID,Nji Akindeh M.25,Netongo Palmer M.25ORCID,Evehe Marie S.25,Atogho-Tiedeu Barbara25,Ghogomu Stephen M.13ORCID,Mbacham Wilfred F.25ORCID

Affiliation:

1. Department of Biochemistry and Molecular Biology, University of Buea, Buea, Cameroon

2. The Biotechnology Centre, University of Yaoundé 1, Yaoundé, Cameroon

3. The Biotechnology Unit, University of Buea, Cameroon

4. Department of Biochemistry, University of Dschang, Dschang, Cameroon

5. Department of Biochemistry, University of Yaoundé 1, Yaoundé, Cameroon

Abstract

Background. Despite recommendation from the World Health Organization that all malaria suspected patients undergo a parasitological confirmation using rapid diagnostic test or light microscopy prior to treatment, health facilities in remote malaria endemic settings sometimes resort to presumptive diagnosis of malaria for clinical management for various reasons. Following observation of this practice, we undertook a cross-sectional study aimed at comparing presumptive diagnosis based on axillary temperature, SD Bioline™ rapid test, and light microscopy as strategies for malaria diagnosis in the coastal region of Mutengene in the South West of Cameroon with the overall goal of supporting improved malaria diagnosis at local levels. Methodology. Venous blood from 320 participants was used to detect the presence of malaria parasite using SD Bioline™ mRDT and Giemsa stained microscopy or spotted on filter paper for PCR amplification of the 18s rRNA gene of Plasmodium sp following standard procedures. The axillary temperature of each participant was also measured. The sensitivity, specificity, and predictive values and their confidence intervals were determined for each of the methods with PCR as the reference. The area under the curve was used to estimate accuracy of diagnostic method and compared between test method using the X2 test with P<0.05 considered significant. Results. The overall diagnostic sensitivities of presumptive diagnosis using axillary temperature, light microscopy, and SD Bioline™ were observed to be 74.30% (95%CI: 67.90-80.01), 94.86% (95%CI: 90.99-97.41), and 95.33% (95%CI: 91.57-97.74), respectively, and their respective diagnostic specificities were 53.77% (95%CI: 43.82-63.51), 94.34% (95%CI: 88.09-97.87), and 94.34%(95%CI: 88.09-97.89). SD Bioline™ had a diagnostic sensitivity of 91.80% [95%CI: 81.90-97.28] at a parasitaemia of less than 500 parasites/μl of blood but a sensitivity of 100% for parasite counts above 500 parasites/μl of blood. The predictive values of the positive test were highly comparable between light microscopy (90.09%, [95%CI: 83.61-94.18]) and SD Bioline™ mRDT (90.91%, [95%CI: 84.50-94.83]), P=0.98 with kappa values of 0.898 but lower for presumptive diagnosis (50.89%, [95%CI: 43.72-58.03]), P<0.0001, and kappa value of 0.277. Perfect agreement was observed between SD Bioline™ mRDT and light microscopy (Cohen kappa= 0.924). Conclusions. The study showed that SD Bioline™ was as good as light microscopy in the diagnosis of malaria in remote areas of perennial transmission in South West Cameroon. This study equally revealed the limitations of presumptive diagnosis of malaria (as opposed to the use of RDTs or microscopy). Efforts should be made in such areas to promote parasitological confirmation of malaria using quality assured rapid tests or light microscopy for case management of malaria. The presence of nonnegligible levels of Plasmodium ovale in this study area indicate that treatment guidelines may require revision if same trend is proven in several other areas of same ecology.

Funder

AESA of the African Academy of Science for Malaria Research and Capacity Development in West and Central Africa

Publisher

Hindawi Limited

Subject

Infectious Diseases,Parasitology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3