Scanning Electron Microscopy Analysis of the Anterior Capsulotomy Edge: A Comparative Study between Femtosecond Laser-Assisted Capsulotomy and Manual Capsulorhexis

Author:

Tognetto Daniele1,De Giacinto Chiara1ORCID,Perrotta Alberto Armando1,Candian Tommaso1,Bova Alessandro1ORCID,Rinaldi Silvia1,Turco Gianluca2ORCID

Affiliation:

1. Eye Clinic, Department of Medicine, Surgery and Health Sciences, University of Trieste, Piazza Ospedale 1, 34129 Trieste, Italy

2. Department of Medicine, Surgery and Health Sciences, University of Trieste, Piazza Ospedale 1, 34129 Trieste, Italy

Abstract

Purpose. To compare the capsule edges ultrastructure obtained by two femtosecond laser-assisted cataract surgery (FLACS) platforms and manual continuous curvilinear capsulorhexis (CCC) using scanning electron microscopy (SEM). Setting. Eye Clinic, University of Trieste, Italy. Design. Experimental comparative study. Methods. 150 anterior capsules were collected and divided into three groups as follows: Group 1 (50 capsules) obtained with manual CCC, Groups 2 and 3 (each with 50 capsules) obtained with the Catalys Laser and the LenSx Laser, respectively. All samples were imaged by means of SEM and regularity of the cut surface, and thickness of the capsule edge were evaluated and compared. Results. All femtosecond laser (FSL) capsules were perfectly circular, whereas some alteration of the circular shape was observed in the manual ones. Group 1 showed a smooth and regular capsule edge without any surface irregularity, conversely Groups 2 and 3 showed postage-stamp perforations on the capsule edge. The cut surface irregularity value in Group 2 was 1.4 ± 0.63, while it was 0.7 ± 0.49 in Group 3 (p<0.05). Group 1 had a significantly lower thickness of the capsule edge than the FSL groups (p<0.05). No statistically significant difference in the capsule edge thickness between the FSL groups was found (p=0.244). Conclusions. Despite the presence of slight cut surface irregularities, both FSL capsulotomies showed a better geometry and circularity than the manual ones. Capsulotomy specimens obtained using both FSL capsulotomies showed laser-induced alterations of the capsule edge when compared with smooth and regular edges obtained using manual CCC.

Publisher

Hindawi Limited

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3