Comparison of Two Tonometers in the Evaluation of 24-Hour Intraocular Pressure and Mean Ocular Perfusion Pressure in Patients with Thyroid-Associated Ophthalmopathy

Author:

Liu Weijie1,Zhou Yao1,Hu Xiaozhou1,Jin Haochen1,Ye Jie1,Xu Mingna1,Liu Zihui1,Wu Wencan1ORCID,Tu Yunhai1ORCID

Affiliation:

1. The Eye Hospital of Wenzhou Medical University, Wenzhou, China

Abstract

Purpose. The aim of the study is to compare a non-contact tonometer (NCT) and goldmann applannation tonometer (GAT) in the evaluation of intraocular pressure (IOP) and mean ocular perfusion pressure (MOPP) in patients with thyroid-associated ophthalmopathy (TAO). Methods. In this study, a total of 30 patients (16 females and 14 males) were recruited. All patients underwent a routine ophthalmic assessment and their medical history was acquired. Clinical assessment included the 24-hour measurement of intraocular pressure and blood pressure, an orbital computed tomography (CT) scan, and a visual field (VF)test. Patients were divided into two groups according to their visual field test results: a defect group with mean deviation (MD) of visual field −2 dB or lower and a normal group with MD over −2 dB. Results. Bland–Altman’s analysis showed similar results of IOP at every time point and revealed an agreement of mean IOP between the two tonometers (the deviation in the mean IOP between the two tonometers was 1 mmHg, with 95% limits of agreement of 8.8 to −6.8 mmHg). The 24-hour MOPP SD value in NCT (2.28) and GAT (1.77) showed that the two instruments had the same diagnostic efficacy (100% sensitivity, 95.8% specificity). The areas under the receiver operator characteristic (ROC) curve of the 24-hour mean ocular perfusion pressure (MOPP) SD (GAT: 0.778, NCT: 0.713; z = 0.669, P = 0.504 ), 24-hour MOPP fluctuation (GAT:0.683, NCT:0.757; z = 0.963, P = 0.336 ) measured by GAT and NCT had no significant difference between the two tonometers. Conclusions. The measurement of IOPs, MOPPs, and their diagnostic efficacy of visual field defect showed consistency between NCT and GAT. The study highlights the importance of monitoring the 24-hour MOPP and IOP in TAO patients. Furthermore, it suggests that the less invasive NCT can replace GAT as a long-term monitoring device in TAO patients.

Funder

Health Commission of Zhejiang Province

Publisher

Hindawi Limited

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3