Comparison of Ocular Morphological Parameters Related to Lens Position by Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy

Author:

Yu Zhiying1ORCID,Wang Fenglei1ORCID,Dong Fang1ORCID,Li Na1ORCID,Wang Dabo1ORCID,Wang Ling1ORCID

Affiliation:

1. Department of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China

Abstract

Objective. The objective is to compare parameters related to lens position measured using anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) in patients with senile cataract and perform a consistency analysis. Methods. This prospective study included 102 patients (102 eyes) scheduled for simple cataract surgery. Among the total patients, 44 were men, and 58 were women. AS-OCT (sitting) and UBM (lying) were used to measure the anterior chamber depth (ACD) in horizontal and vertical orientations and the iris-lens contact distance (ILCD) and iris-lens angle (ILA) in inferior, superior, nasal, and temporal quadrants. Paired-sample t-test was used to compare ACD, ILCD, and ILA measurements of the two methods, while Pearson’s linear correlation and Bland-Altman analyses were used to analyze the correlation and consistency of the two results. Results. The horizontal (2.499 ± 0.464 mm) and vertical (2.531 ± 0.463 mm) ACD measured using AS-OCT and the horizontal (2.556 ± 0.467 mm) and vertical (2.563 ± 0.479 mm) ACD measured using UBM were significantly different ( P < 0.001 ); moreover, the results showed good correlation and agreement. A significant difference was observed between the two methods in terms of ILCD measured in inferior, superior, nasal, and temporal quadrants ( P < 0.001 ), and a significant correlation was found between measurements of both methods ( P < 0.001 ). Approximately 3.92% (4/102), 0.98% (1/102), 3.92% (4/102), and 2.94% (3/102) of points were outside the 95% limits of agreement in the four quadrants, respectively, and the agreement of the results was good. ILA measured using both methods differed in inferior, superior, nasal, and temporal quadrants ( P = 0.003 , 0.011, 0.001, 0.001, respectively), and the correlation was good ( P < 0.001 ). The percentage of points outside the 95% limit was higher in inferior, superior, nasal, and temporal quadrants (4.90% (5/102), 5.88% (6/102), 5.88% (6/102), and 6.86% (7/102)) with poor agreement of the results. Conclusions. The correlation between AS-OCT and UBM in terms of measuring lens position-related parameters was good, but the agreement was unstable. The differences in measurement position (sitting and supine) and/or measurement methods (optics and ultrasound) may lead to variability in results.

Funder

Qingdao University

Publisher

Hindawi Limited

Subject

General Medicine

Reference29 articles.

1. Anterior lens displacement with age;R. F. Lowe;British Journal of Ophthalmology,1970

2. Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy;Z. Y. Yu;World Journal of Clinical Cases,2020

3. Comparison of ultrasound biomicroscopy and spectraldomain anterior segment optical coherence tomography in evaluation of anterior segment after laser peripheral iridotomy;X. Y. Ma;International Journal of Ophthalmology,2016

4. Prospective comparison of ultrasound biomicroscopy and anterior segment optical coherence tomography for evaluation of anterior chamber dimensions in European eyes with primary angle closure;K. Mansouri;Eye,2010

5. Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment;T. Dada;Journal of Cataract and Refractive Surgery,2007

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3