Affiliation:
1. Department of Architecture and Building Engineering, Tokyo Institute of Technology, Tokyo 152-8552, Japan
Abstract
Hybrid structure has shown some great features in the earthquake-resistant design. However, due to the different properties between the combined building systems, the distributions of structural mass and stiffness are prevalently irregular in breadth or height, which makes the widely used equivalent lateral force (ELF) method powerless to predict the seismic shear force of such hybrid structure. This study proposed a simple design procedure for determining the concerned seismic shear force of low-rise wooden horizontal hybrid structure in the preliminary linear design. The dual equivalent lateral force (DELF) method is presented that permits the extension of the ELF method by separating the hybrid structure into two independent substructures. It is shown that the proposed DELF method is sufficient to provide a reasonable estimation of the seismic shear force with satisfied accuracy.
Subject
Mechanical Engineering,Mechanics of Materials,Geotechnical Engineering and Engineering Geology,Condensed Matter Physics,Civil and Structural Engineering
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献