Clinical Outcome and Biomechanical Analysis of Dynamic Hip Screw Combined with Derotation Screw in Treating Displaced Femoral Neck Fractures Based on Different Reduction Qualities in Young Patients (≤65 Years of Age)

Author:

Zhu Jian12345ORCID,Li Yonglong345ORCID,Zhang Yingze1345ORCID,Cheng Xiaodong345ORCID

Affiliation:

1. School of Medicine, Nankai University, Tianjin 300071, China

2. Shanxi Bethune Hospital, Shanxi Academy of Medical Science, No. 99, Longcheng Street, Taiyuan, 030032 Shanxi Province, China

3. Department of Orthopaedic Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang 050051, China

4. Key Laboratory of Biomechanics of Hebei Province, Orthopaedic Research Institution of Hebei Province, Shijiazhuang, 050051 Hebei, China

5. NHC Key Laboratory of Intelligent Orthopeadic Equipment (The Third Hospital of Hebei Medical University), Shijiazhuang 050051 Hebei, China

Abstract

Objective. To examine the clinical results and biomechanical mechanism of the dynamic hip screw (DHS) and derotation screw (DS) in the treatment of displaced femoral neck fractures (FNF) based on different reduction qualities in young patients (≤65 years of age). Methods. All patients with FNF who received closed reduction and internal fixation with DHS+DS from January 2014 to August 2019 were retrospectively analyzed. Data on demographics, surgery, clinical outcomes, and postoperative complications were collected. According to the reduction quality immediately after surgery, all patients were categorized into the positive buttress reduction group (PBRG) and the anatomical reduction group (ARG). The complications and clinical outcomes were compared between the two groups. Meanwhile, the biomechanical mechanism of different reduction qualities was further analyzed with finite element analysis (FEA). The distribution of von Mises stress, the peak stress of internal fixation, and the displacement of the proximal fragment were compared between the two groups. Results. A total of 68 patients were included in our study. Among them, 31 were divided into the PBRG while 37 were in the ARG. The surgical time and fluoroscopy time were significantly shorter in the PBRG than in the ARG ( p < 0.05 ). The degree of femoral neck shortening and the varus change of the femoral-neck shaft angle were lower in the PBRG compared to the ARG ( p < 0.05 ). The excellent-good rate of the Harris hip score was higher in the PBRG compared to the ARG (83.9% vs. 64.8%). The FEA results demonstrated that the stress of DHS+CS and the downward displacement of the proximal femoral neck fragment were greater in the ARG than in the PBRG. Conclusion. For displaced FNF with difficulty to achieve reduction, DHS+CS combined with positive buttress reduction was an effective treatment in young patients due to better mechanical support, shorter surgical time, less radiation exposure, and higher excellent-good rate of Harris hip score.

Funder

Chinese Academy of Medical Sciences

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

Reference40 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3