Abstract

Purpose. Although full-wave simulations could be used to aid in RF coil design, the algorithms may be too slow for an iterative optimization algorithm. If quasistatic simulations are accurate within the design tolerance, then their use could reduce simulation time by orders of magnitude compared to full-wave simulations. This paper examines the accuracy of quasistatic and full-wave simulations at 3 Tesla. Methods. Three sets of eight coils ranging from 3–10 cm (24 total) were used to measure SNR on three phantoms with conductivities of 0.3, 0.6, and 0.9 S/m. The phantom conductivities were chosen to represent those typically found in human tissues. The range of coil element sizes represents the sizes of coil elements seen in typical coil designs. SNR was determined using the magnetic and electric fields calculated by quasistatic and full-wave simulations. Each simulated SNR dataset was scaled to minimize the root mean squared error (RMSE) when compared against measured SNR data. In addition, the noise values calculated by each simulation were compared against benchtop measured noise values. Results. The RMSE was 0.285 and 0.087 for the quasistatic and full-wave simulations, respectively. The maximum and minimum quotient values, when taking the ratio of simulated to measured SNR values, were 1.69 and 0.20 for the quasistatic simulations and 1.29 and 0.75 for the full-wave simulations, respectively. The ratio ranges, for the calculated quasistatic and full-wave total noise values compared to benchtop measured noise values, were 0.83–1.06 and 0.27–3.02, respectively. Conclusions. Full-wave simulations were on average 3x more accurate than the quasistatic simulations. Full-wave simulations were more accurate in characterizing the wave effects within the sample, though they were not able to fully account for the skin effect when calculating coil noise.

Funder

Siemens USA

Publisher

Hindawi Limited

Subject

Physical and Theoretical Chemistry,Spectroscopy,Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3