Abstract
The paper illustrates the design and the implementation of a Fault Detection and Isolation (FDI) system to a rotary machine like a multishaft centrifugal compressor. A model-free approach, that is, the Principal Component Analysis (PCA), has been employed to solve the fault detection issue. For the fault isolation purpose structured residuals have been adopted while an adaptive threshold has been designed in order to detect and to isolate the faults. To prove the goodness of the proposed FDI system, historical data of a nitrogen centrifugal compressor employed in a refinery plant are considered. Tests results show that detection and isolation of single as well as multiple faults are successfully achieved.
Subject
Industrial and Manufacturing Engineering,Mechanical Engineering
Cited by
8 articles.
订阅此论文施引文献