Abstract

Study hypothesis. We sought to investigate the association between echocardiographic optimisation and ventricular activation time in cardiac resynchronisation therapy (CRT) patients, obtained through the use of electrocardiographic mapping (ECM). We hypothesised that echocardiographic optimisation of the pacing delay between the atrial and ventricular leads—atrioventricular delay (AVD)—and the delay between ventricular leads—interventricular pacing interval (VVD)—would correlate with reductions in ventricular activation time. Background. Optimisation of AVD and VVD may improve CRT patient outcome. Optimal delays are currently set based on echocardiographic indices; however, acute studies have found that reductions in bulk ventricular activation time correlate with improvements in acute haemodynamic performance. Materials and methods. Twenty-one patients with established CRT criteria were recruited. After implantation, patients underwent echo-guided optimisation of the AVD and VVD. During this procedure, the participants also underwent noninvasive ECM. ECM maps were constructed for each AVD and VVD. ECM maps were analysed offline. Total ventricular activation time (TVaT) and a ventricular activation time index (VaT10-90) were calculated to identify the optimal AVD and VVD timings that gave the minimal TVaT and VaT10-90 values. We correlated cardiac output with these electrical timings. Results. Echocardiographic programming optimisation was not associated with the greatest reductions in biventricular activation time (VaT10-90 and TVaT). Instead, bulk activation times were reduced by a further 20% when optimised with ECM. A significant inverse correlation was identified between reductions in bulk ventricular activation time and improvements in LVOT VTI (p<0.001), suggesting that improved ventricular haemodynamics are a sequelae of more rapid ventricular activation. Conclusions. EAM-guided programming optimisation may achieve superior fusion of activation wave fronts leading to improvements in CRT response.

Funder

National Institute for Health Research

Publisher

Hindawi Limited

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3