Heart-Protective Mechanical Ventilation in Postoperative Cardiosurgical Patients

Author:

Mazurok Vadim1ORCID,Kasherininov Igor1,Bautin Andrey1,Kulemina Olga1,Rzheutskaya Ryta1

Affiliation:

1. Almazov National Medical Research Centre, Akkuratova St, 2, Saint Petersburg 197341, Russia

Abstract

Background. This study compared the hemodynamic effects and gas exchange under several different ventilator settings—with regard to tidal volume, respiratory rate, and end-expiratory pressure—in patients after coronary artery bypass grafting (CABG). Methods. Prospective interventional cohort study with a controlled group in a single cardiosurgical ICU involving 119 patients following on-pump CABG surgery. During the 1st postoperative hour, the intervention group patients were ventilated with Vt 10 ml × kg−1, RR 14/min, PEEP 5 cmH2O (“conventional ventilation”). During the 2nd hour, RR was reduced to 8/min (“reduced RR ventilation”). At 3 hrs, Vt was decreased to 6 ml × kg−1, RR returned to 14/min, and PEEP increased to 10 cmH2O (“low Vt-high PEEP ventilation”). Results. Patients in the “low Vt-high PEEP” ventilation period showed significantly lower alveolar ventilation and thoraco-pulmonary compliance than during “reduced RR” ventilation. Mean airway pressure and Vds/Vt peaked during low Vt-high PEEP ventilation; however, driving pressure was lower. Vt decrease and PEEP increase did not lead to oxygenation improvement and worsened CO2 elimination. Hemodynamically, the study revealed significant cardiac output decrease during low Vt-high PEEP ventilation. In 23.2% of patients, catecholamine therapy was initiated. Conclusions. In postoperative cardiosurgical patients, MV with Vt 6 ml × kg−1 and PEEP 10 cm H2O is characterized by worsened oxygenation and elimination of CO2 and a less favorable hemodynamic profile than ventilation with Vt 10 ml × kg−1 and PEEP 5 cmH2O. New and Noteworthy. (i) Patients after CABG may be especially sensitive to low tidal volume and increased PEEP as it negatively affects hemodynamic profile by means of the right heart preload decrease and afterload increase. (ii) Mechanical ventilation settings aiming to minimize mean airway pressure reduce the negative effects of positive inspiratory pressure and are favorable for hemodynamics.

Publisher

Hindawi Limited

Subject

Critical Care and Intensive Care Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3