Affiliation:
1. National Institute of Drug Quality Control, Ministry of Health, Hanoi, Vietnam
2. Department of Analytical Chemistry and Toxicology, Hanoi University of Pharmacy, Hanoi, Vietnam
Abstract
A simple, easy-to-implement, and green infrared spectroscopic method was developed and validated for the quantitative determination of sildenafil citrate in tablets of unknown manufacturing formula. Homogenized tablet powder with known mass content (%, m/m) of sildenafil citrate was mixed with paracetamol to form standard mixtures with different percentages of sildenafil citrate on the total quantity of sildenafil citrate and paracetamol (designated as R). Unknown tablet samples were finely ground and mixed with paracetamol to form test mixtures having R values about 50%. Infrared spectra of standard mixtures, measured in attenuated total reflectance mode, in the wavenumber zone from 1800 cm−1 to 1300 cm−1 were selected and processed by partial least square regression to form the calibration model for quantitation of sildenafil citrate in unknown samples. Spectral responses of test mixtures and the calibration model were used to determine the exact mass content (%, m/m) of sildenafil citrate in the powder of unknown tablet samples. The method was fully validated in terms of linearity, precision, and accuracy according to the requirements of current guidelines and was proved as reliable and suitable for the intended application.
Subject
Computer Science Applications,Instrumentation,General Chemical Engineering,Analytical Chemistry
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献