Malapposed Struts with Cre8, Biomatrix, and Xience Stents Assessed with OCT Immediately after Implantation and at 6-Month Follow-Up: Can the Different Biomechanical Characteristics of the Three Stents Impact on Struts Malapposition?

Author:

Giglioli Cristina12ORCID,Cecchi Emanuele1,Formentini Chiara3,Chiostri Marco3,Marchionni Niccolò13,Romano Salvatore Mario13

Affiliation:

1. Division of General Cardiology, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy

2. Department of Cardiovascular and Thoracic Medicine, Azienda Ospedaliero-Universitaria Careggi, Viale G.B. Morgagni 85, Florence 50134, Italy

3. Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy

Abstract

Background. Although the clinical effects of stent malapposition remain controversial, several analyses of stent registries consistently have found that malapposed struts were frequently identified in patients who experienced stent thrombosis. In this study, which is a subanalysis of the previously published CREBX-OCT study, we compared optical coherence tomography (OCT) analysis at the index percutaneous coronary intervention (PCI) and at six-month follow-up in 37 patients randomly assigned to receive, by a single operator, three different second-generation drug-eluting stents (Cre8, Biomatrix, and Xience) aiming to clarify if the malapposition observed at six-month follow-up was persistent or late-acquired. Moreover, we investigated if there were some differences in the behavior of the three different kinds of stents in relation to the struts malapposition. Material and Methods. We analyzed 614 and 599 cross sections and 5514 and 5377 struts at the index PCI and at six-month follow-up, respectively. The qualitative analysis of the plaque composition among the three groups did not show significant differences. Results. The lumen area did not significantly change from the index procedure to the six-month follow-up in the three groups; on the contrary, the number of malapposed struts increased significantly in the Cre8 and Biomatrix groups but not in the Xience group: 0.58 ± 1.51 and 3.29 ± 5.33 ( p < 0.023 ) in the Cre8 group, 0.55 ± 1.81 and 1.73 ± 2.28 ( p < 0.024 ) in the Biomatrix group, and 0.55 ± 1.5 and 0.25 ± 0.87 ( p < 0.166 ) in the Xience group, respectively. Conclusions. Therefore, the malapposition observed at six-month follow-up in our study population could be mainly considered as acquired and attributable to biomechanical reasons due to the structural differences among the three stents. This trial is registered with Clinical Trials.gov Identifier: NCT02850497.

Funder

Abbott CV

Publisher

Hindawi Limited

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3