Reliability of the DIERS Formetric 4D Spine Shape Parameters in Adults without Postural Deformities

Author:

Degenhardt Brian F.12ORCID,Starks Zane1ORCID,Bhatia Shalini3

Affiliation:

1. A.T. Still Research Institute, A.T. Still University, Kirksville, MO 63501, USA

2. Department of Osteopathic Manipulative Medicine, A.T. Still University, Kirksville College of Osteopathic Medicine, Kirksville, MO 63501, USA

3. Department of Research Support, A.T. Still University, Kirksville, MO 63501, USA

Abstract

The DIERS formetric 4D provides a safe method to monitor and track the progression of postural deformities over time. However, further evaluation of reliability is necessary. Reference values are also needed to indicate postural change. The current study examined the reliability of spine shape parameters produced by the formetric 4D in adults without postural abnormalities and established reference values to determine when real change occurs. Thirty participants were scanned during 1 week. Intraclass correlation coefficients (ICCs) were calculated for 40 spine shape parameters for scans with participants stationary between scans, scans with repositioning between scans, and between days. Within-day and between-day standard error of measurement (SEM), absolute relative SEM, and smallest detectable change (SDC) were reported. ICC for stationary scans was excellent for 29 parameters, good for 10 parameters, and fair for 1 parameter. With repositioning, ICC was excellent for 27 parameters, good for 12 parameters, and fair for 1 parameter. Between days, ICC was excellent for 26 parameters, good for 10 parameters, and fair for 4 parameters. Within-day SEM% was greater than 10% for 6 parameters. Within-day SDC ranged from 1.80 to 25.03 units for a single scan and from 0.97 to 17.93 units for 6 scans. Between-day SEM% was greater than 10% for 9 parameters. Between-day SDC ranged from 1.44 to 28.24 units for a single scan and from 1.05 to 22.2 units for 6 scans. Thirty-six of the 40 spine shape parameters from the DIERS formetric 4D reliably distinguished between participants over time. Reference values were established that can be used to track patient postural change over time. Future research should investigate the clinical relevance of these 40 spine shape parameters and determine when a clinically important change in posture occurs.

Funder

Osteopathic Heritage Foundation

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3