To Investigate Whether Hematocrit Affects Thromboelastography Parameters

Author:

Zhang Min1ORCID,He Keyu1,Ye Dong2,Zhang Qiang1,Zhang Zhengkang1

Affiliation:

1. Department of Blood Transfusion, Zhongda Hospital, School of Medicine, Southeast University, Nanjing 210009, China

2. Department of Blood Transfusion, Affiliated Taikang Xianlin Drum Tower Hospital, Medical School of Nanjing University, Nanjing 210093, China

Abstract

Background. Thromboelastogram (TEG) is an experiment to detect coagulation function with whole blood. Red blood cell (RBC) is the most abundant component of blood. Whether RBC has an impact on the results of thromboelastogram? Study Design and Methods. The correlation between hematocrit (HCT) and TEG was analyzed. 17 samples were reconstituted with different HCT. They were tested separately. Correction tests were performed on 17 samples from patients with anemia. HCT was corrected to 0.40 in female and 0.45 in males. The correction formula was determined according to the experimental correction. Results. HCT was negatively correlated with TEG parameters. As HCT increased, CI and angle decreased ( P < 0.05 , P < 0.001 ) and K increased ( P < 0.001 ) in reconstituted samples. In the correction test, the angle measured value was 69.48 ± 4.98 and corrected value was 62.48 ± 6.25, MA measured value was 61.44 ± 7.10 and corrected value was 55.94 ± 7.12, K measured value was 1.45 ± 0.48 and corrected value was 2.11 ± 0.79, and CI measured value was 1.07 ± 1.67 and corrected value was −0.45 ± 1.64. There was a significant difference. The correction formulas of anemia were derived from the experimental correction results. KCorrection value = (0.7903∗A2 − 2.1803A + 2.8268)∗KMeasured value; Tan angleCorrection value = Tan angleMeasured value/(0.6596∗A2 − 1.7478A + 2.4608); MACorrection value = MAMeasured value/(0.1853ln (A) + 1.0197); CICorrection value = −0.6516RMeasured value − 0.3772KCorrection value + 0.1224MACorrection value + 0.0759angleCorrection value − 7.7922. Conclusion. HCT has a negative impact on TEG parameters. Coagulation state of anemia patients is overestimated by TEG. The test results of anemia patients need to be corrected whether through the experimental correction or the formula correction.

Funder

Second Batch of Industry-University Cooperative Education Projects in 2021

Publisher

Hindawi Limited

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3