Affiliation:
1. Anesthesiology and Reanimation Department, Ataturk Training and Research Hospital, Ankara, Turkey
2. Faculty of Medicine, University of Yıldırım Beyazıt, Ankara, Turkey
Abstract
A 79-year-old woman, diagnosed for cancer of the ovary, had a central catheter that was placed with difficulty through the right internal jugular vein intraoperatively. After oophorectomy, it was realized that the catheter was knotted. Thus, the central venous catheter was removed successfully using a traction technique in the operating room. Central venous catheter use may result in various complications, although it has been used as an invasive method for hemodynamic monitoring and fluid and drug infusion. Here, we present catheter knotting in a case with solutions for this complication, under literature review.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献