Effect of Gingival Hemostatic Agents on the Surface Detail Reproduction and Dimension Stability of Three Elastomeric Impression Materials

Author:

Chiaraputt Sirichan1ORCID,Chokwattanapornchai Nattida1ORCID,Limchaikul Katanyoo1ORCID,Paisarnkobrit Vibul1ORCID,Sriamporn Tool2ORCID

Affiliation:

1. Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Srinakharinwirot University, Bangkok, Thailand

2. Department of Prosthodontics, College of Dental Medicine, Rangsit University, Prathum Thani, Thailand

Abstract

This study aimed to evaluate the effects of aluminum chloride based hemostatic agents on the surface detail reproduction and dimension stability. Three impression materials were investigated after contaminated with three commercial astringents with different concentration of aluminum chloride. The specimens from three impression materials were fabricated with a stainless-steel mold that followed the American Dental Association specification no.19. The mold was preliminarily contaminated with three hemostatic agents racestyptine, Dryz, and Expasyl™—and 80 specimens from each impression material—polyvinylsiloxane (PVS), polyether, and polyvinylsiloxane ether (PVSE), were fabricated and subjected to each astringent. The surface detail reproduction was examined using a stereomicroscope at 4x magnification, and the dimensional stability was analyzed at 24 hr with a measuring microscope. The surface detail data were statistically analyzed with Fisher’s test at a significance level of 0.05. The dimensional stability data were analyzed using two-way ANOVA and Tukey’s test at a significance level of 0.05. Aluminum chloride hemostatic agents can affect the surface detail reproduction of impression materials differently ( p < 0.05 ). Thus, the first null hypothesis was rejected. PVS showed the highest percentage of satisfactory surface detail regardless of the hemostatic agent used in this study. PVSE showed a reduced percentage of satisfactory surface detail when the concentration of aluminum chloride was high. The three hemostatic agents affected the dimensional stability of each material differently ( p < 0.05 ). Therefore, the second null hypothesis was also rejected.

Funder

Srinakharinwirot university

Publisher

Hindawi Limited

Subject

General Dentistry

Reference25 articles.

1. Review and survey of medicaments used with gingival retraction cords

2. Disturbance of the dentinal smear layer by acidic hemostatic agents

3. A review of contemporary impression materials and techniques

4. Effect of 3 different medicament on dimensional stability and surface detail reproduction of polyvinyl siloxane impression material;K. C. Vaishnav;National Journal of Integrated Research in Medicine,2012

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3