A Method to Evaluate and Eliminate Fungal Contamination in Household Air Conditioners

Author:

Shiraishi Yoshiki1ORCID,Harada Kazuhiro2,Maeda Chikao2,Ogino Fumitoshi2,Suzuki Yu3,Okada Naoki1,Tomomatsu Katsuyoshi1,Sekine Yoshika4,Yanagi U.5,Imanishi Tadashi3,Oguma Tsuyoshi1,Asano Koichiro1ORCID

Affiliation:

1. Division of Pulmonary Medicine, Department of Medicine, Tokai University School of Medicine, Kanagawa, Japan

2. Research and Development, Duskin Co., Ltd., Suita, Osaka, Japan

3. Department of Molecular Life Science, Tokai University School of Medicine, Kanagawa, Japan

4. Department of Chemistry, School of Science, Tokai University, Kanagawa, Japan

5. Department of Architecture, School of Architecture, Kogakuin University, Tokyo, Japan

Abstract

Background. Allergic fungal airway diseases, such as asthma and allergic bronchopulmonary mycosis (ABPM), are often difficult to manage with medical treatment alone; therefore, environmental fungal exposure should be accurately evaluated and minimized. In the present study, we established a method to evaluate and eliminate fungal contamination in household air conditioners (ACs). Methods. In the fall of 2020, an environmental survey of living rooms was conducted in 17 Japanese residences of patients with ABPM or related diseases. Household ductless minisplit AC units were disassembled to collect swab samples from the internal parts (filter, heat exchanger, blower fan, and air vent), followed by high-pressure washing. Fungal abundance and composition in swab samples and cleaning effluents of ACs as well as house dust and air samples were determined using quantitative PCR and next-generation sequencing of the internal transcribed spacer 1 region, respectively. A weighted UniFrac distance was calculated to analyze the similarity of the mycobiome among the samples. Results. All interior parts of ACs contained high levels of fungal DNA, with the blower fans being the most contaminated parts. Cladosporium and Toxicocladosporium, followed by Aureobasidium, Aspergillus, and Rhodotorula, were the most common fungi detected in the AC unit. High-pressure washing decreased fungal abundance by over 99% in all AC parts. Fungal abundance and composition in blower fans were strongly correlated with those in cleaning effluents. Conclusion. Interior parts downstream of heat exchangers in household ACs are the major sites of fungal contamination, possibly polluting the indoor air in the residences. High-pressure washing is highly effective for decontamination.

Funder

Tokai University

Publisher

Hindawi Limited

Subject

Public Health, Environmental and Occupational Health,Building and Construction,Environmental Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3