Effect of Proparacaine 0.375%-Sodium Fluorescein 0.25% Eye Drop Mixture and Fluorescein Strip on Anterior Segment Parameters

Author:

Doğan Mustafa1ORCID,Sabaner Mehmet Cem1,Erol Mehmet Akif1ORCID

Affiliation:

1. Faculty of Medicine, Department of Ophthalmology, Afyon Kocatepe University, Afyonkarahisar, Turkey

Abstract

Purpose. To determine the effect of proparacaine 0.375%-sodium fluorescein 0.25% eye drop mixture and fluorescein strip on anterior segment parameters commonly used in routine ophthalmology practice. Methods. 115 healthy volunteers without any systemic or ocular disease were divided into two groups. 57 volunteers were in the proparacaine 0.375%-sodium fluorescein 0.25% eye drop mixture group, and 58 volunteers were in the fluorescein strip group. Measurements (CCT (central corneal thickness), topographic pupil diameter, AD (aqueous depth), ACV (anterior chamber volume), ICA (iridocorneal angle), LLD (limbus-limbus distance), and CV (corneal volume)) were taken before and at 1, 5, 15, and 30 minutes after application. Results. 59 (51.3%) participants were female, and 56 (48.7%) were male. The mean age of the drop application group was 26.88 ± 8.03, and the mean age of the strip application group was 26.33 ± 7.28. The mean CCT was 556 ± 32 μm before drop application and 569 ± 30 μm in the 1st minute, 560 ± 32 μm in the 5th minute, and 559 ± 31 μm in the 15th minute. The change was statistically significant (p<0.001, p=0.005, and p=0.013, resp.). Before the strip application, mean CCT was 552 ± 36 μm, while it increased to 556 ± 36 μm at the 1st minute, and this change was statistically significant (p=0.002). The mean CV before dropping was 59.29 ± 3.53 mm3 and 60.62 ± 3.53 mm3 at the 1st minute and 59.66 ± 3.70 mm3 at the 5th minute, which was statistically significant (p<0.001 and p=0.034). Mean topographic pupil diameters at the 1st, 5th, 15th, and 30th minute after application of drops and strips were not significantly changed compared to the preapplication values in the AD, ACV, ICA, and LLD measurements. Conclusions. Proparacaine 0.375%-sodium fluorescein 0.25% eye drop mixture and fluorescein strip application lead to a temporary change in CCT and CV of the anterior segment parameters. Anterior segment measurements with the Scheimpflug camera have to be done before topical fluorescein application.

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3