Determination of Chlorpromazine, Haloperidol, Levomepromazine, Olanzapine, Risperidone, and Sulpiride in Human Plasma by Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)

Author:

Khelfi Abderrezak12ORCID,Azzouz Mohammed3,Abtroun Rania1,Reggabi Mohammed3,Alamir Berkahoum12

Affiliation:

1. Department of Toxicology, Bab-El-Oued hospital, Avenue Mohamed Lamine Debaghine, 16009, Algiers, Algeria

2. National Center of Toxicology, Avenue Petit Staouali Delly Brahim, 16062, Algiers, Algeria

3. Department of Biology and Toxicology, Ait-Idir hospital, Avenue Abderrezak Hahad Casbah, 16017, Algiers, Algeria

Abstract

Background and Objective. In this study, turbo-ion spray as an interface of tandem mass spectrometry (MS/MS) was performed for sensitive and accurate quantification of chlorpromazine, haloperidol, levomepromazine, olanzapine, risperidone, and sulpiride in plasma samples. Methods. Separation was performed by gradient reversed phase high-performance liquid chromatography using a mobile phase containing ammonium formiate 2 mM, pH 2.7, and acetonitrile flowing through a Restek PFP Propyl C18 analytical column (50 mm×2.1 mm i.d.) with particle size of 5 µm, at a flow rate of 800 µL/min. Positive ion fragments were detected in multiple reaction monitoring (MRM) mode. Sample preparation was achieved by solid phase extraction (SPE) (Oasis HLB). Results. Mean extraction recoveries ranged from 82.75% to 100.96%. The standard calibration curves showed an excellent linearity, covering subtherapeutic, therapeutic, and toxic ranges. Intraday and interday validation using quality control (QC) samples were performed. The inaccuracy and imprecision were below 12% at all concentration levels. The limits of detection (LOD) and quantification (LOQ) for all analytes were under therapeutic ranges for all tested analytes. Thus, the proposed method was sensitive enough for the detection and determination of subtherapeutic levels of these antipsychotics in plasma samples. No interference of endogenous or exogenous molecules was observed and no carryover effects were recorded. Conclusion. According to the results, the proposed method is simple, specific, linear, accurate, and precise and can be applied for antipsychotic analysis in clinical routine. This method was applied for the determination of the tested antipsychotics in plasma samples taken from 71 individuals.

Publisher

Hindawi Limited

Subject

Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3