Effect of Implant Positions and Angulations on Retentive Strength of 2-Implant Mandibular Overdentures: An In Vitro Study with the New 3D-Printed Simulation Method

Author:

Patil Pravinkumar G.1ORCID,Seow Liang Lin1ORCID,Uddanwadikar Rashmi2ORCID,Pau Allan3ORCID,Ukey Piyush D.4ORCID

Affiliation:

1. Division of Restorative Dentistry, School of Dentistry, International Medical University, Kuala Lumpur, Malaysia

2. Department of Mechanical Engineering, Visvesvaraya National Institute of Technology, Nagpur, India

3. Division of Clinical Oral Health Sciences, School of Dentistry, International Medical University, Kuala Lumpur, Malaysia

4. NU OSSA Mediquip Pvt Ltd, Nagpur, India

Abstract

Objectives. To evaluate the retentive strength of overdenture attachments in 2-implant mandibular overdenture (2IMO) with implants placed at different positions and angulations. Materials and Methods. Edentulous mandibular models were 3D-printed using CBCT images and Materialise Mimics software and the denture models using the intraoral scanner. Two standard implants were placed parallel at different positions from midline (5, 10, 15, and 20 mm) with 0-0 degree angulations and with different distal angulations (0–5, 0–10, 0–15, 5-5, 10-10, and 15-15 degrees) at 10±mm from midline representing 10 study groups. Low-profile male attachments were attached to the implants and the female pink attachments were picked up in the denture. A total of 4 simulated overdenture model sets for each of the 10 study groups were subjected to the universal testing machine thrice to measure a peak load (N) to disengage the attachments vertically. Data were analyzed using one-way ANOVA and Tukey’s post hoc test at 0.05 significance level. Results. Varying implant positions had a statistically significant effect on the retentive strengths of the attachments (F = 5.61, P = 0.002 ). Peak load-to-dislodgement values (in increasing order) were 49.64 ± 8.27 N for 5 mm, 53.26 ± 11.48 N for 10 mm, 60.24 ± 12.31 N for 15 mm, and 64.80 ± 6.78 N for 20 mm groups. The retentive strength of the 20 mm group was significantly higher than 5 mm ( P = 0.003 ) and 10 mm ( P = 0.03 ) groups. Varying implant angulations had a significant effect on the retentive strengths of the attachments (F = 7.412, P = 0.000 ). The peak load-to-dislodgement values (in increasing order) were 48.20 ± 15.59 N for 5-5 degrees, 53.26 ± 11.48 N for 0-0 degrees, 54.96 ± 8.25 N for 0–5 degrees, 57.71 ± 7.62 N for 10-10 degrees, 66.00 ± 17.54 N for 15-15 degrees, 66.18 ± 14.09 N for 0–10 degrees, and 77.38 ± 10.33 N for 0–15 degrees. Retentive strength of 0–15 degrees was significantly ( P < 0.05 ) higher than those of 0-0, 0–5, 5-5, and 10-10 degrees and that of 5-5 degrees was significantly ( P < 0.05 ) lower than those of 0–10, 0–15, and 15-15 groups. Conclusions. Retentive strength of the 2IMO increased with increase in distance of implants from midline and increased with increase in distal angulations.

Funder

Ministry of Higher Education, Malaysia

Publisher

Hindawi Limited

Subject

General Dentistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3