The Influence of Decentration on Higher-Order Aberrations in Artisan Aphakic Intraocular Lens Implantation Eyes

Author:

Miao Aizhu12,Zhang Min12ORCID,Chen Tianhui12,Lu Yi12ORCID

Affiliation:

1. Department of Ophthalmology and Vision Science, Eye and ENT Hospital of Fudan University, Shanghai, China

2. NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences and Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai, China

Abstract

Purpose. To characterize the influence of decentration on higher-order aberrations of Artisan aphakic intraocular lens implantation eyes. Setting. Department of Ophthalmology and Vision Science, Eye and ENT Hospital of Fudan University, Shanghai, China. Design. Retrospective case series. Methods. Twenty-three eyes of 18 patients were retrospectively examined. Location of the IOL was imaged using a slit-lamp, and decentration (the distance from the center of a pupil to the geometric center of the IOL) was measured using the AutoCAD 2007 software. Ocular and internal higher-order aberrations were measured using the wavefront analyzer KR-1W (Topcon) and their correlation with decentration were analyzed. Coma, spherical, 3rd-, 4th-order, trefoil, tetrafoil aberrations, ocular, and internal higher-order aberrations were calculated for a 4.0 mm pupil diameter. Results. The mean age of patients was 33.6 ± 21.4 years (ranging from 7 to 72 years). The mean follow-up period was 28.2 ± 10.5 months (ranging from 12 to 52 months). The mean postoperative best-corrected visual acuity (BCVA) was 0.19 ± 0.19 logMAR (range −0.18–0.52). The mean decentration was 0.57 ± 0.28 mm (range 0.15–1.21 mm). There was no correlation between Artisan IOL decentration and ocular higher-order aberrations, internal higher-order aberrations, coma, spherical, 3rd-, 4th-order, trefoil, and tetrafoil aberrations, respectively. There was a positive correlation between Artisan IOL decentration and 2nd-astig aberrations when 2nd-astig aberrations were less than 0.1. Conclusions. The position of Artisan IOLs showed slight decentration and the amounts of decentration were not large enough to influence higher-order aberrations.

Funder

National Natural Science Foundation of China

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3