Affiliation:
1. Tianjin Key Laboratory of Structural Protection and Reinforcement for Civil and Construction, Tianjin Chengjian University, Tianjin 300384, China
Abstract
Based on the research of composite walls at home and abroad, a construction method of continuous opening of the insulation layer in the specimen is proposed. In the edge component of the composite wall, the insulation layer should be thinned appropriately, the concrete on both sides should be thickened correspondingly, and U-shaped reinforcement should be used instead of stirrup. To study its axial compression test performance, five 1/2 scale composite shear wall specimens are tested under axial compression, including three composite wall specimens and two solid wall contrast specimens. The failure mode, load-bearing performance, deformation performance, and the collaborative work performance of wall are analyzed. The results show that the failure characteristics of the composite shear wall are similar to those of the solid wall, with splitting cracks at the corners and inverted triangular conical splitting at the top of the wall along the wall height direction, with no obvious bulging in the middle of the wall. The tie action of the ribs makes the concrete walls on both sides of the composite shear wall have good integrity and cooperative performance; the installation of the thermal insulation layer increases the overall thickness of the wall, improves the stability of the composite wall, and makes the composite wall axially compressed. The bearing capacity is not significantly reduced compared to the solid walls. Finally, according to the test results, the calculation formula of axial compression bearing capacity of composite shear wall is given, which provides the basis for the formulation of the code and engineering application.
Subject
Civil and Structural Engineering
Reference21 articles.
1. Experimental study on axial performance of composite wall with interior insulation;Y. H. Hao;Journal of Building Structures,2015
2. Full Scale Testing of Precast Concrete Sandwich Panels
3. Testing and acceptance criteria for fiber-reinforced composite grid connectors used in concrete sandwich panels;M. Ekenel,2013
4. New shear connector design for insulated concrete sandwich panels using basalt fiber-reinforced polymer bars;D. G. Tomlinson;American Society of Civil Engineers,2016
5. Compressive behavior of double skin composite wall with different plate thicknesses;Y. Qin;Journal of Constructional Steel Research,2019