The Topographical Effect of Optical Zone Diameter in Orthokeratology Contact Lenses in High Myopes

Author:

Carracedo G.1ORCID,Espinosa-Vidal T. M.1,Martínez-Alberquilla I.1,Batres L.1

Affiliation:

1. Department of Optics II (Optometry and Vision), Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain

Abstract

Purpose. To evaluate the effect of the optical zone diameter (OZ) in orthokeratology contact lenses regarding the topographical profile in patients with high myopia (−4.00 D to −7.00 D) and to study its effect over the visual quality. Materials and Methods. Twelve patients (18 eyes) were fitted with overnight orthokeratology (OrthoK) with a randomized 6 mm or 5 mm OZ lens worn for 2 weeks, followed by a 2-week washout period, between both designs. Keratometry (K) readings, optical zone treatment diameter (OZT), peripheral ring width (PRW), higher-order aberrations (HOA), high (HC) and low contrast (LC) visual acuity, and subjective vision and comfort were measured at baseline and after 2 weeks of OrthoK lens wear of each contact lens. Results. No significant differences were found between any measurements for the same subject at both baselines (p value > 0.05). There was no difference between OZ lens designs found in refraction, subjective vision or comfort, and HC and LC visual acuity. Contrast sensitivity was decreased in the 5 mm OZ lens design compared with 6 mm OZ design (p-value < 0.05). 5 mm OZ design provoked a greater flattening, more powerful midperipheral ring and 4th-order corneal and total spherical aberration than the 6 mm OZ design, being statistically significant after 7 days, for corneal aberration, and 15 days, for corneal and total, of wearing the lens (p-value < 0.05). The OZT obtained were 2.8 ± 0.2 mm and 3.1 ± 0.1 mm for 5 mm and 6 mm OZ design, respectively (p-value < 0.05). Regarding PRW, the 5 mm OZ design had a wider ring width in both the nasal and temporal zones (p-value < 0.05). Conclusions. A smaller diameter optical zone (5 mm) in orthokeratology lenses produces a smaller treatment area and a larger and more powerful midperipheral ring, increasing the 4th-order spherical aberration that affects only the contrast sensitivity but without differences in visual acuity and subjective vision compared with a larger OZ diameter (6 mm).

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3