OCT Biometry (B-OCT): A New Method for Measuring Ocular Axial Dimensions

Author:

Sikorski Bartosz L.12ORCID,Suchon Pawel12

Affiliation:

1. Department of Ophthalmology, Nicolaus Copernicus University, 9 M. Sklodowskiej-Curie St., Bydgoszcz 85-309, Poland

2. Oculomedica Eye Center, 9 Broniewskiego St., Bydgoszcz 85-316, Poland

Abstract

Purpose. To present a new method of measuring ocular axial dimensions, termed OCT biometry (B-OCT). Design. Observational cross-sectional study and evaluation of new diagnostic technology. Methods. B-OCT was implemented in the spectral domain OCT device for posterior and anterior segment imaging (REVO NX, Optopol Technology). A total of 349 eyes (214 of healthy subjects, 115 of patients with cataract, and 20 with severe macular diseases) were enrolled in the study. The results of B-OCT were compared to swept source OCT-based IOLMaster 700 (Carl Zeiss Meditec). Differences in measurement values between the two biometers were determined using the paired t-test. Agreement was assessed through intraclass correlation coefficients (ICCs) and Bland–Altman plots. Results. B-OCT obtained with REVO NX provides excellent interobserver reproducibility (ICC for: axial length (AXL) = 1.000; central corneal thickness (CCT) = 0.933; anterior chamber depth (ACD) = 0.933; lens thickness (LT) = 0.985) and intraobserver repeatability (ICC for: AXL = 1.000; CCT ≥ 0.994; ACD = 0.998; LT ≥ 0.993). The correlation between measurements made using both devices was outstanding (ICC for: AXL, healthy = 1.000; AXL, cataractous = 1.000; ACD, healthy = 0.998; ACD, cataractous = 0.997; LT, healthy = 0.998; LT, cataractous = 0.997; CCT, healthy = 0.989; CCT, cataractous = 0.979). The mean AXL measurement difference in healthy eyes was −0.001 ± 0.016 mm (the 95% LoA ranged from −0.034 to 0.031); mean ACD difference was 0.000 ± 0.024 mm (95% LoA, −0.047 to 0.047); mean LT difference was −0.002 ± 0.024 mm (95% LoA, −0.050 to 0.046); and mean CCT difference  was −0.8 ± 5.1 μm (95% LoA, −10.81 to 9.26). The mean AXL measurement difference in cataractous eyes was −0.003 ± 0.022 mm (95% LoA, −0.046 to 0.039); mean ACD difference was 0.003 ± 0.029 mm (95% LoA, −0.054 to 0.059); mean LT difference was −0.002 ± 0.025 (95% LoA, −0.051 to 0.048); and mean CCT difference was 2.7 ± 6.4 μm (95% LoA, −9.80 to 15.7). Conclusion. The study shows small, nonsignificant differences between the biometric measurements obtained with REVO NX B-OCT and IOLMaster 700, which is of high significance for IOL power selection. As B-OCT utilizes a conventional OCT device, the measurements of the ocular axial dimensions are combined with high-resolution macular scans for the simultaneous assessment of central retina as a part of screening for macular pathology. The presented method is the first spectral domain OCT-based biometry technique and the only one integrated into a standard OCT device. Thus, it brings novel functionality to OCT technology.

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3