In Vitro Effect of the Length of Relocated Cervical Margin with Casting Post and Core, Prefabricated Fiber Post, and Polyethylene Fiber with a Composite Core on Fracture Resistance and Marginal Integrity

Author:

Musapoor NaghmehORCID,Neshandar Asli HamidORCID,Mokhtari SorooshORCID,Babaee Hemmati YasaminORCID,Falahchai MehranORCID

Abstract

Objective. This study aimed to assess the effect of length of the relocated cervical margin with casting post and core (CP), prefabricated fiber post and composite core (PFP), and polyethylene fiber‐reinforced composite (PEFRC) on fracture resistance and marginal integrity. Materials and Methods. In this in vitro study, 70 sound human maxillary premolars were divided into seven groups according to the type of post and core system and length of the relocated cervical margin (n = 10): control (no preparation), PFP‐3, PEFRC‐3, CP‐3 with 3 mm of cervical margin relocation (CMR), PFP‐6, PEFRC‐6, and CP‐6 (with 6 mm of CMR). The samples were restored with zirconia crowns (except the control group). Epoxy resin replicas were fabricated before and after thermomechanical loading. Marginal integrity was assessed at the luting cement‐core, core‐tooth, and luting cement‐enamel interfaces under a scanning electron microscope (SEM) (×200). Fracture resistance and failure mode were subsequently assessed. Data were analyzed by independent t‐test, paired t‐test, ANOVA, Tukey–Games Howell, Mann–Whitney, Kruskal–Wallis, Wilcoxon, Mann–Whitney with Bonferroni correction, and Fisher–Freeman–Halton tests (α = 0.05). Results. The marginal integrity of the groups with 3 mm of CMR followed the following order: PEFRC > PFP > CP at all interfaces (P  < 0.05). In 6‐mm CMR groups, this order was CP < PFP = PEFRC at the luting cement‐core and (CP < PEFRC) = PFP at the core‐tooth interface. No significant difference was found in fracture resistance when comparing the 3‐mm CMR groups with each other (P  > 0.05). PFP‐6 showed higher FR than CP‐6 (P  < 0.001). PEFRC‐6 had no significant difference with PFP‐6 and CP‐6 (P  > 0.05). In each post and core system, 3‐mm CMR groups showed higher marginal integrity and fracture resistance (P  < 0.05). Conclusion. Increasing the length of the relocated cervical margin decreased the marginal integrity and fracture resistance of all three systems of CP, PFP, and PEFRC.

Funder

Guilan University of Medical Sciences

Publisher

Wiley

Reference45 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3