MRI Images under the Optimized Registration Algorithm for Primary Open Angle Glaucoma Visual Path Damage

Author:

Zhou Bin1ORCID,Chen Min2ORCID

Affiliation:

1. Department of Ophthalmology, Tonglu First People's Hospital, Hangzhou, China

2. Department of Ophthalmology, Ophthalmologic Center of the Second Affiliated Hospital of Zhejiang University, Hangzhou, China

Abstract

To explore the impact of different image registration algorithms on the diagnosis of visual path damage in patients with primary open angle glaucoma (POAG), 60 cases of suspected POAG patients were selected as the research objects. Shape-preserving scale invariant feature transform (SP-SIFT) algorithm, scale invariant feature transform (SIFT) algorithm, and Kanade-Lucas-Tomasi (KLT) algorithm were compared and applied to MRI images of 60 POAG patients. It was found that the SP-SIFT algorithm converged after 33 iterations, which had a higher registration speed than the SIFT algorithm and the KLT algorithm. The mean errors of the SP-SIFT algorithm in the rotation angle, X-direction translation, and Y-direction translation were 2.11%, 4.56%, and 4.31%, respectively. Those of the SIFT algorithm were 5.55%, 9.98%, and 7.01%, respectively. Those of the KLT algorithm were 7.45%, 11.31%, and 8.56%, respectively, and the difference among algorithms was significant ( P < 0.05 ). The diagnostic sensitivity and accuracy of the SP-SIFT algorithm for POAG were 96.15% and 94.34%, respectively. Those of the SIFT algorithm were 94.68% and 90.74%, respectively. Those of the KLT algorithm were 94.21% and 90.57%, respectively, and the three algorithms had significant differences ( P < 0.05 ). The results of MRI images based on the SP-SIFT algorithm showed that the average thickness of the cortex of the patient’s left talar sulcus, right talar sulcus, left middle temporal gyrus, and left fusiform gyrus were 2.49 ± 0.15 mm, 2.62 ± 0.13 mm, 3.00 ± 0.10 mm, and 2.99 ± 0.17 mm, respectively. Those of the SIFT algorithm were 2.51 ± 0.17 mm, 2.69 ± 0.12 mm, 3.11 ± 0.13 mm, and 3.09 ± 0.14 mm, respectively. Those of the KLT algorithm were 2.35 ± 0.12 mm, 2.52 ± 0.16 mm, 2.77 ± 0.11 mm, and 2.87 ± 0.17 mm, respectively, and the three algorithms had significant differences ( P < 0.05 ). In summary, the SP-SIFT algorithm was ideal for POAG visual pathway diagnosis and was of great adoption potential in clinical diagnosis.

Publisher

Hindawi Limited

Subject

Computer Science Applications,Software

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3