Computed Tomography Angiography and B-Mode Ultrasonography under Artificial Intelligence Plaque Segmentation Algorithm in the Perforator Localization for Preparation of Free Anterolateral Femoral Flap

Author:

Shen Dan1,Huang Xuehui1ORCID,Huang Yinwei1,Zhou Dandan1,Ye Shasha1

Affiliation:

1. Department of Hand Foot and Micro-Surgery, Yuyao People’s Hospital, Ningbo 315400, Zhejiang, China

Abstract

This research was aimed to investigate the accuracy of U-shaped network (UNet)-based computed tomography angiography (CTA) and B-mode ultrasonography (US) in the perforator localization of free anterolateral thigh flap (ALTF). Based on UNet, a fusion of deep supervision mechanism, squeeze-and-excitation module, and attention mechanism was introduced to optimize the algorithm. Then, a CTA segmentation model, DA-UNet, was established. The segmentation performance of DA-UNet and other algorithms was compared under the same conditions. 30 patients who were planned to receive ALTF surgery were selected as the research objects. According to different preoperative localization methods, they were divided into group A (CTA) and group B (B-mode US), 15 cases in each group. Combined with the actual situation during surgery, the diagnostic accordance rate, sensitivity (Sen), specificity, and the distance between the perforator location and the actual location were compared between the two groups. The Dice coefficient, Jaccard index, Sen, the area under curve (AUC), and average Hausdorff distance (AVD) of the DA-UNet segmentation algorithm were 80.70%, 69.97%, 77.56%, 0.887, and 2.48, respectively. These results were significantly better than those of other algorithms ( P < 0.05 ). In group A, the diagnostic accordance rate, Sen, and specificity of patients were 96.55%, 90.52%, and 73.58%, respectively, which were higher than 91.53%, 81.36%, and 15.60% of patients in group B significantly ( P < 0.05 ). There was no statistical difference in the distance between the perforator location and the actual location ( P > 0.05 ). It showed that the accuracy of CTA under the UNet-based DA-UNet segmentation model in the perforator localization of ALTF was better than that of B-mode US. Thus, a reference could be provided for the preparation of free ALTF and its clinical application.

Publisher

Hindawi Limited

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3