Transcutaneous Intraluminal Impedance Measurement for Minimally Invasive Monitoring of Gastric Motility: Validation in Acute Canine Models

Author:

Poscente Michael D.1,Wang Gang1,Filip Dobromir2,Ninova Polya3,Muench Gregory4,Yadid-Pecht Orly2,Mintchev Martin P.125,Andrews Christopher N.6

Affiliation:

1. Centre for Bioengineering and Research, University of Calgary, Engineering Complex, 2500 University Drive NW, Calgary, AB, Canada T2N 1N4

2. Department of Electrical and Computer Engineering, University of Calgary, Engineering Complex, 2500 University Drive NW, Calgary, AB, Canada T2N 1N4

3. Division of Pediatrics, Faculty of Medicine, University of Calgary, Calgary, AB, Canada T2N 1N4

4. Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada T2N 1N4

5. Department of Surgery, Faculty of Medicine, University of Alberta, Edmonton, AB, Canada T6G 2B7

6. Division of Gastroenterology, Faculty of Medicine, University of Calgary, Calgary, AB, Canada T2N 1N4

Abstract

Transcutaneous intraluminal impedance measurement (TIIM) is a new method to cutaneously measure gastric contractions by assessing the attenuation dynamics of a small oscillating voltage emitted by a battery-powered ingestible capsule retained in the stomach. In the present study, we investigated whether TIIM can reliably assess gastric motility in acute canine models.Methods. Eight mongrel dogs were randomly divided into 2 groups: half received an active TIIM pill and half received an identically sized sham capsule. After 24-hour fasting and transoral administration of the pill (active or sham), two force transducers (FT) were sutured onto the antral serosa at laparotomy. After closure, three standard cutaneous electrodes were placed on the abdomen, registering the transluminally emitted voltage. Thirty-minute baseline recordings were followed by pharmacological induction of gastric contractions using neostigmine IV and another 30-minute recording. Normalized one-minute baseline and post-neostigmine gastric motility indices (GMIs) were calculated and Pearson correlation coefficients (PCCs) between cutaneous and FT GMIs were obtained. Statistically significant GMI PCCs were seen in both baseline and post-neostigmine states. There were no significant GMI PCCs in the sham capsule test. Further chronic animal studies of this novel long-term gastric motility measurement technique are needed before testing it on humans.

Funder

Natural Sciences and Engineering Research Council of Canada

Publisher

Hindawi Limited

Subject

Gastroenterology,Hepatology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Modeling and imaging of intestinal electrical impedance based on conjugate gradient method;International Journal for Numerical Methods in Biomedical Engineering;2020-08-10

2. Magnetically guided capsule endoscopy;Medical Physics;2017-06-23

3. Enhanced electrogastrography: A realistic way to salvage a promise that was never kept?;World Journal of Gastroenterology;2017

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3