Affiliation:
1. Department of Civil Engineering, Northeastern University, Shenyang, Liaoning Province, China
Abstract
During the vibration of a transmission tower, the joints will be subjected to a reciprocating load. To obtain the accurate state of the transmission tower under the load, the mechanical properties of the joints under the vibration load must be considered. In this paper, the mechanical properties of typical K-joints in transmission tower structures are studied by numerical simulation. The failure mode of the K-joint under cyclic loading is also analyzed. The mechanical properties of the K-joint are discussed from the aspects of hysteretic characteristics, stiffness degradation, energy dissipation capacity, and ductility evaluation, and the influencing factors are discussed. The results show that the failure mode of the K-joint is related to the bolt grade and steel strength. When analyzing K-joints, the moment-rotation hysteresis curve should be combined with the realistic parameters of joints to consider the hysteretic behavior of the K-joint. The results provide a theoretical reference for the accurate modeling of transmission towers.
Funder
National Natural Science Foundation of China
Subject
Mechanical Engineering,Mechanics of Materials,Geotechnical Engineering and Engineering Geology,Condensed Matter Physics,Civil and Structural Engineering
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献