Dosimetry and Comparison between Different CT Protocols (Low Dose, Ultralow Dose, and Conventional CT) for Lung Nodules’ Detection in a Phantom

Author:

Leitão Cleverson Alex1,Salvador Gabriel Lucca de Oliveira1ORCID,Tazoniero Priscilla1,Warszawiak Danny1,Saievicz Cristian1,Jakubiak Rosangela Requi2,Escuissato Dante Luiz1

Affiliation:

1. Department of Radiology, Universidade Federal do Paraná, Curitiba, Paraná, Brazil

2. Universidade Tecnológica Federal do Paraná, Curitiba, Paraná, Brazil

Abstract

Background. The effects of dose reduction in lung nodule detection need better understanding. Purpose. To compare the detection rate of simulated lung nodules in a chest phantom using different computed tomography protocols, low dose (LD), ultralow dose (ULD), and conventional (CCT), and to quantify their respective amount of radiation. Materials and Methods. A chest phantom containing 93 simulated lung nodules was scanned using five different protocols: ULD (80 kVp/30 mA), LD A (120 kVp/20 mA), LD B (100 kVp/30 mA), LD C (120 kVp/30 mA), and CCT (120 kVp/automatic mA). Four chest radiologists analyzed a selected image from each protocol and registered in diagrams the nodules they detected. Kruskal–Wallis and McNemar’s tests were performed to determine the difference in nodule detection. Equivalent doses were estimated by placing thermoluminescent dosimeters on the surface and inside the phantom. Results. There was no significant difference in lung nodules’ detection when comparing ULD and LD protocols ( p = 0.208 to p = 1.000 ), but there was a significant difference when comparing each one of those against CCT ( p < 0.001 ). The detection rate of nodules with CT attenuation values lower than −600 HU was also different when comparing all protocols against CCT ( p < 0.001 to p = 0.007 ). There was at least moderate agreement between observers in all protocols (κ-value >0.41). Equivalent dose values ranged from 0.5 to 9 mSv. Conclusion. There is no significant difference in simulated lung nodules’ detection when comparing ULD and LD protocols, but both differ from CCT, especially when considering lower-attenuating nodules.

Publisher

Hindawi Limited

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3