Abstract

Aim. To investigate the relationship between stent length and changes in microvascular resistance during PCI in stable coronary artery disease (CAD). Methods and Results. We measured fractional flow reserve (FFR), index of microcirculatory resistance (IMR), and coronary flow reserve (CFR) before and after stenting in 42 consecutive subjects with stable coronary artery undergoing PCI with stent in the LAD. Patients that had very long stent length (38–78 mm) had lower FFR before stenting than patients that had long (23–37 mm) and moderate (12–22 mm) stent length (0.59 (±0.16), 0.70 (±0.12), and 0.75 (±0.07); p=0.002). FFR improved after stenting and more so in subjects with very long stent length compared to long and moderate stent length (0.27 (s.d ± 16), 0.15 (s.d ± 0.12), and 0.12 (s.d ± 0.07); p for interaction = 0.013). Corrected IMR (IMRcorr) increased after stenting in subjects who had very long stent length, whereas IMRcorr was lower after stenting in subjects who had long or moderate stent length (4.6 (s.d. ± 10.7), −1.4 (s.d. ± 9,9), and −4.2 (s.d. ± 7.8); p for interaction = 0.009). Conclusions. Changes in IMR during PCI in the LAD in stable CAD seem to be related to total length of stents implanted, possibly influencing post-PCI FFR. Larger studies are needed to confirm the relationship.

Publisher

Hindawi Limited

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3