Measurement of Liver Iron Concentration by MRI Is Reproducible

Author:

Alústiza José María1,Emparanza José I.2,Castiella Agustín3,Casado Alfonso4,Garrido Adolfo5ORCID,Aldazábal Pablo6,San Vicente Manuel1,Garcia Nerea6,Asensio Ana Belén6,Banales Jesús7,Salvador Emma1,Moyua Aranzazu8,Arozena Xabier9,Zarco Miguel9,Jauregui Lourdes10,Vicente Ohiana10

Affiliation:

1. Osatek, Donostia Universitary Hospital, P. Dr. Beguiristain 109, 20014 Donostia/San Sebastián, Spain

2. Clinical Epidemiology, Donostia Universitary Hospital, P. Dr. Beguiristain 117, 20080 Donostia/San Sebastián, Spain

3. Gastroenterology, Mendaro Hospital, Mendarozabal s/n, Mendaro, Spain

4. Basque Country University, Avenida Tolosa 54, 20018 Donostia/San Sebastián, Spain

5. Biochemical Laboratory, Donostia Universitary Hospital, P. Dr. Beguiristain 117, 20080 Donostia/San Sebastián, Spain

6. Experimental Department, Donostia Universitary Hospital, P. Dr. Beguiristain 117, 20080 Donostia/San Sebastián, Spain

7. Liver Diseases Unit, Biodonostia Research Institute, P. Dr. Beguiristain s/n, 20014 Donostia/San Sebastián, Spain

8. Policlínica Gipúzkoa, Paseo Miramón 174, 20014 Donostia/San Sebastián, Spain

9. Radiology, Quirón Donostia Hospital, Alkolea Parkea 7, 20012 Donostia/San Sebastián, Spain

10. Onkologikoa, P. Dr. Beguiristain s/n, 20011 Donostia/San Sebastián, Spain

Abstract

Purpose. The objectives were (i) construction of a phantom to reproduce the behavior of iron overload in the liver by MRI and (ii) assessment of the variability of a previously validated method to quantify liver iron concentration between different MRI devices using the phantom and patients.Materials and Methods. A phantom reproducing the liver/muscle ratios of two patients with intermediate and high iron overload. Nine patients with different levels of iron overload were studied in 4 multivendor devices and 8 of them were studied twice in the machine where the model was developed. The phantom was analysed in the same equipment and 14 times in the reference machine.Results. FeCl3solutions containing 0.3, 0.5, 0.6, and 1.2 mg Fe/mL were chosen to generate the phantom. The average of the intramachine variability for patients was 10% and for the intermachines 8%. For the phantom the intramachine coefficient of variation was always below 0.1 and the average of intermachine variability was 10% for moderate and 5% for high iron overload.Conclusion. The phantom reproduces the behavior of patients with moderate or high iron overload. The proposed method of calculating liver iron concentration is reproducible in several different 1.5 T systems.

Funder

Carlos III Health Institute, Madrid

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3