Efficacy and Safety of Photon Induced Photoacoustic Streaming for Removal of Calcium Hydroxide in Endodontic Treatment

Author:

Laky Markus1ORCID,Volmer Melanie1ORCID,Arslan Muazzez1ORCID,Agis Hermann1ORCID,Moritz Andreas12,Cvikl Barbara13ORCID

Affiliation:

1. Division of Conservative Dentistry and Periodontology, School of Dentistry, Medical University of Vienna, Vienna, Austria

2. Division of Dental Student Training and Patient Care, School of Dentistry, Medical University of Vienna, Vienna, Austria

3. Department of Preventive, Restorative and Pediatric Dentistry, School of Dentistry, University of Bern, Bern, Switzerland

Abstract

Calcium hydroxide removal from the root canal by photon induced photoacoustic streaming (PIPS) compared to needle irrigation and irrigation using sonic activation was investigated. Additionally, safety issues regarding apical extrusion were addressed. In endodontic treatment temporary intracanal medication like calcium hydroxide should be completely removed for long term success. For analysis, 60 artificial teeth were prepared, filled with calcium hydroxide, and divided into four groups. The teeth were assigned to needle irrigation, irrigation using a sonic device, PIPS with a lower energy setting (10 mJ, 15 Hz), or PIPS with a higher energy setting (25 mJ/40 Hz). For comparison the weight of each tooth was measured before and after calcium hydroxide incorporation, as well as after removing calcium hydroxide using the four different methods. Regarding safety issues another 24 samples were filled with stained calcium hydroxide and embedded in 0.4% agarose gel. Color changes in the agarose gel due to apical extrusion were digitally analysed using Photoshop. No significant differences were found for calcium hydroxide removal between the two laser groups. Sonic assisted removal and needle irrigation resulted in significant less calcium hydroxide removal than both laser groups, with significantly more calcium hydroxide removal in the ultrasonic group than in the needle irrigation group. For apical extrusion the higher laser (25 mJ/40 Hz) group resulted in significant higher color changes of the periapical gel than all other groups. PIPS with the setting of 10 mJ/15 Hz achieved almost complete removal of calcium hydroxide without increasing apical extrusion of the irrigation solution.

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3