Fluence Rate in UV Photoreactor for Disinfection of Water: Isotropically Radiating Cylinder

Author:

Ilinsky Roman1,Ulyanov Andrey1

Affiliation:

1. Joint Stock Company “Svarog”, Stromynka Street 18, Moscow 107014, Russia

Abstract

The calculation of fluence rate in the photochemical reactor using ultraviolet (UV) radiation for disinfection of water for the case, when a cylinder of infinite length is used as a light source, has been considered. Such a cylinder is filled with an isotropically radiating medium. The dependence of the fluent rate on the diameter of the radiating cylinder has been analytically analyzed. The limiting case when the diameter of the radiating cylinder tends to zero has been considered and the notion of “effective interval” has been introduced. Based on this notion, the comparison of fluence rates for the cylinders of finite and infinite lengths has been performed. In the calculations of fluence rate, it is advisable to use the Chebyshev method for the operations of numerical integration.

Publisher

Hindawi Limited

Subject

General Chemical Engineering