Flapless and Conjunctiva-Sparing Technique for Transscleral Fixation of Intraocular Lens to Correct Refractive Errors in Eyes without Adequate Capsular Support

Author:

Lou Wei1,Chen Ziang1,Huang Yang1,Jin Haiying12ORCID

Affiliation:

1. Department of Ophthalmology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China

2. Department of Ophthalmology, Shanghai Tenth People’s Hospital, Tongji University School of Medicine, Shanghai, China

Abstract

Purpose. To evaluate refractive outcomes, intraocular lens (IOL) power calculation, and IOL position following a novel conjunctiva-sparing transscleral fixation technique. Methods. Forty-one eyes of 40 patients managed with a flapless transscleral-sutured technique were included. Preoperative and postoperative refractive errors (spherical equivalents, SE) were compared. IOL position was assessed on the Scheimpflug images. IOL power was calculated by SRK/T, Holladay 1, and Hoffer Q formulas. Results. The mean age was 57.39 ± 14.83 years (range: 26 to 79 years), and the mean follow-up was 7.46 ± 6.42 months (range: 1 to 24 months). Surgical indications were aphakia (n = 14), subluxated lenses (n = 3), and IOL dislocation (n = 24). The SE was 4.50 ± 6.38 diopter (D) (range: −3.75 to 13.75 D) preoperatively and −1.68 ± 1.57 D (range: −5.50 to 1.13 D) postoperatively ( P < 0.001 ). The mean tilt angle and decentration were 2.90° ± 1.93° (range: 0.39° to 9.10°) and 0.23 ± 0.19 mm (range: 0.02 to 0.94 mm) vertically, and 1.75° ± 1.41° (range: 0.24° to 7.65°) and 0.18 ± 0.19 mm (range: 0.02 to 1.06 mm) horizontally, which were clinically insignificant. All three IOL formulas produced myopic errors (range: −0.29 to −0.50 D). The SRK/T had the lowest median absolute error (0.55 D), followed by the Holladay 1 (0.70 D) and the Hoffer Q (0.74 D). The three formulas had the same percentage of prediction errors (PEs) within ±0.5 D (43.48%), while the Hoffer Q had the highest percentage of PEs within ±1.0 D (82.61%). Conclusion. The present technique can serve as an alternative approach for transscleral IOL fixation and refractive correction in eyes with compromised capsular support, ensuring the stability of IOLs and reasonable IOL power calculation accuracy.

Funder

Science and Technology Innovation Plan Of Shanghai Science and Technology Commission

Publisher

Hindawi Limited

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3