Abstract
Rotor-to-stator rub is a very common topic in rotor dynamics and several models have been proposed in the literature. Anyhow these models are often able to explain only the experimental dynamical behaviour of simple test rigs, which are deliberately reproducing a Jeffcott rotor. On the contrary case, histories related to real machines are seldom presented and analysed. The aim of this paper is to present an actual case history of a large turbogenerator unit that was subjected to partial arc rubs. The experimental results are shown and discussed along with the model-based diagnostic strategy employed to identify the fault severity and the location of the shaft cross-sections where the heaviest rubs occurred. Comparisons between experimental data and simulated vibrations caused by the identified fault are shown to validate the proposed methodology.
Subject
Industrial and Manufacturing Engineering,Mechanical Engineering
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献