Slender Sheath/Guiding Catheter Combination vs. Sheathless Guiding Catheter for Acute Coronary Syndrome: A Propensity-Matched Analysis of the Two Devices

Author:

Isawa Tsuyoshi1ORCID,Horie Kazunori1,Honda Taku1,Taguri Masataka2,Tada Norio1

Affiliation:

1. Department of Cardiology, Sendai Kousei Hospital, Sendai, Japan

2. Department of Data Science, Yokohama City University School of Data Science, Yokohama, Japan

Abstract

A Glidesheath slender (Terumo, Tokyo, Japan) and a sheathless Eaucath guiding catheter (Asahi Intecc, Nagoya, Japan) are two major slender devices utilized in percutaneous coronary intervention (PCI). This study aimed to investigate the differences in access-site complications between these devices in PCI for acute coronary syndrome (ACS). A total of 1108 consecutive patients who underwent transradial PCI for ACS were enrolled. Transradial PCI was performed using either a 7-Fr Glidesheath slender/7-Fr guiding catheter combination (Glidesheath group) or a 7.5-Fr sheathless guiding catheter (Sheathless group); 1 : 1 propensity score matching was performed, and 728 patients (364 in each group) were included in the propensity-matched population. In the matched patients, univariate analysis revealed that the Glidesheath group had less radial artery occlusion (RAO) at 30 days (Glidesheath: 1.4% vs. Sheathless: 4.1%, odds ratio (OR) = 0.33, 95% confidence interval (CI) =  0.12–0.91, p=0.039), whereas no significant between-group differences were observed in severe radial spasm (Glidesheath: 1.4% vs. Sheathless: 1.9%, OR = 0.71, 95% CI = 0.23–2.22, p=0.58) or access-site major bleeding (Glidesheath: 1.4% vs. Sheathless: 1.6%, OR = 0.83, 95% CI = 0.26–2.71, p=1.00). Multivariate analysis revealed that the choice for Glidesheath was significantly associated with less RAO (OR = 0.32, 95% CI = 0.11–0.93, p=0.036). In conclusion, 7-Fr Glidesheath slender/7-Fr guiding catheter combination is obviously more advantageous than 7.5-Fr sheathless guiding catheters for decreased risk of RAO. The potential low risk of RAO in our findings supports the adoption of the 7-Fr Glidesheath slender sheath/7-Fr guiding catheter combination in transradial PCI for ACS.

Publisher

Hindawi Limited

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3