Analysis of the Application Value of Different Esophagography Techniques in the Diagnosis of H-Type Tracheoesophageal Fistula in Neonates

Author:

Deng Kewei1,Luo Liqian1ORCID

Affiliation:

1. Neonatal Department, Northwest Women and Children’s Hospital, Xi’an City, Shaanxi Province 710061, China

Abstract

Objective. The study aimed to analyse the detection rates of the triple-lumen double-balloon catheter technique and conventional esophagography in diagnosing H-type tracheoesophageal fistula (H-TEF) in neonates. Methods. The data of 8 neonates diagnosed with H-TEF by surgery in the researchers’ hospital between January 2015 and January 2022 were collected. We compared the detection (true positive) rates of H-TEF by the triple-lumen double-balloon catheter technique, conventional esophagography, and multidetector row spiral CT. Results. Before surgery, conventional esophagography was applied in all 8 cases, of which the H-TEF diagnosis was confirmed in 5 cases and TEF was suspected in 3 cases. The triple-lumen double-balloon catheter technique was employed in 5 cases, of which 4 were confirmed with H-TEF and 1 was suspected with TEF. Multidetector row spiral CT was performed in 4 cases, and 1 case was confirmed with H-TEF, while no fistula was observed in the other 3 cases. The triple-lumen double-balloon catheter technique yielded a 100% detection rate, while conventional esophagography revealed a 62.5% rate and multidetector row spiral CT showed a 25% rate. By comparative analysis, the true positive rates (TPRs) of the triple-lumen double-balloon catheter technique and conventional esophagography were not significantly different ( P = 0.118 ). No significant differences were recorded in TPRs between conventional esophagography and multidetector row spiral CT ( P = 0.221 ). However, the triple-lumen double-balloon catheter technique had a significantly higher TPR than multidetector row spiral CT ( P = 0.118 ). Conclusion. To diagnose congenital H-TEF in neonates, conventional esophagography is a highly valuable yet inconsistently reliable method and the diagnostic value of CT is relatively limited. The triple-lumen double-balloon catheter technique boasts a significantly valuable application for H-TEF diagnosis. Being simple, economical, and effective, it barely requires state-of-the-art facilities, and no complications have occurred during its clinical practice. These advantages justify a possible wider application of the triple-lumen double-balloon catheter technique in clinical practice.

Publisher

Hindawi Limited

Subject

Complementary and alternative medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3