Impact of Hydrostatic Pressure Variations Caused by Height Differences in Supine and Prone Positions on Fractional Flow Reserve Values in the Coronary Circulation

Author:

Kawaguchi Yoshitaka1ORCID,Ito Kazuki1,Kin Humihiko1,Shirai Yusuke1,Okazaki Ayako1,Miyajima Keisuke1,Watanabe Tomoyuki1,Tatsuguchi Mariko1,Wakabayashi Yasushi1,Maekawa Yuichiro2ORCID

Affiliation:

1. Department of Cardiology, Seirei Mikatahara General Hospital, Hamamatsu, Shizuoka, Japan

2. Internal Medicine III, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan

Abstract

Objectives. To examine the influence of hydrostatic pressure on fractional flow reserve (FFR) in vivo.Background. Systematic differences in FFR values have been observed previously in the left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA). It has been suggested that as the hydrostatic pressure variations caused by the height differences between the catheter tip (mean aortic pressure (Pa)) and pressure-wire sensor (mean distal intracoronary pressure (Pd)) are small, intracoronary pressure need not be corrected.Methods. Resting Pd/Pa and FFR values in 23 patients (27 lesions) were measured and compared in supine and prone positions. These values were corrected by hydrostatic pressure influenced by height levels and compared. Height differences between Pa and Pd were calculated using coronary computed tomography angiographies.Results. In LAD, resting Pd/Pa and FFR values were significantly higher in the prone position than in the supine position (0.97 ± 0.05 vs 0.89 ± 0.04,P<0.001(resting Pd/Pa); 0.81 ± 0.09 vs 0.72 ± 0.07,P<0.001(FFR)). Conversely, in LCX and RCA, these values were significantly lower in the prone position (LCX: 0.93 ± 0.03 vs 0.98 ± 0.03,P<0.001(resting Pd/Pa); 0.84 ± 0.05 vs 0.89 ± 0.04,P<0.001(FFR); RCA: 0.91 ± 0.04 vs 0.98 ± 0.03,P=0.005(resting Pd/Pa); 0.78 ± 0.07 vs 0.84 ± 0.07,P=0.019(FFR)). FFR values corrected by hydrostatic pressure showed good correlations in the supine and prone positions (R2 = 0.948 in LAD;R2 = 0.942 in LCX;R2 = 0.928 in RCA).Conclusions. Hydrostatic pressure variations due to height levels influence intracoronary pressure measurements and largely affect resting Pd/Pa and FFR, which might have caused systematic differences in FFR values between the anterior and posterior coronary territories.

Publisher

Hindawi Limited

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3