Evaluation of Three Human-Use Glucometers for Blood Glucose Measurement in Dogs

Author:

Santos Matheus Albuquerque Basilio dos1ORCID,Vargas Alesssandra Martins2,Rosato Paula Nunes3,Andrade Carolina Gomes4,Martins Camila Marinelli5,Petri Giuliana1

Affiliation:

1. Metropolitan University of Santos (UNIMES)-Prefeito Antônio Manoel de Carvalho Avenue, 3935 Morro Nova Cintra 11080-100, Santos, Sao Paulo, Brazil

2. College Anclivepa Ulisses Cruz Avenue, 285 Tatuapé 03077-000, Santos, Sao Paulo, Brazil

3. Anclivet Veterinary Laboratory Goias Street, 118, Gonzaga 11050-100, Santos, Sao Paulo, Brazil

4. São Judas Tadeu University Comendador Martins Street, 52, Vila Matias, 11015-530, Santos, Sao Paulo, Brazil

5. AAC&T Research Consulting LTDA Domingas Vigo Zaninelli Street, Boa Vista 82540-096, Curitiba, Parana, Brazil

Abstract

Background. Glucometers or portable sensors are used to quickly measure blood glucose at low cost. They are used in veterinary practice and by guardians to monitor diseases that require, as in diabetes mellitus. However, not all commercially available glucometers (human and veterinary) are suitable for this purpose. Hypotheses/Objectives. The objective was to evaluate the analytical and clinical precision of three human-use portable glucometers. Animals. This study evaluated 115 samples in three glycemic ranges (hypoglycemia, normoglycemia, and hyperglycemia) from 82 dogs recruited from veterinary services. Methods. The portable glucometers are the FreeStyle Freedom Lite®, FreeStyle Optium Neo®, and On Call Plus® models. Glucometer results were compared with the enzymatic colorimetric glucose oxidase laboratory reference method. Using descriptive and comparative statistical analysis, there were correlations between these devices and the standard method, ISO 15197 : 2003 and ISO 15197 : 2013 standards, and error grid analysis. Results. Only the Freedom Lite® device observed a statistical difference when compared with the reference method. Despite the underestimated glucose concentrations assessed with humane devices, all three tested herein showed a positive coefficient. However, none of these achieved all ISO guidelines. Conclusion and Clinical Importance. Although there was wide use of portable humane devices for dog glucose measurements on routine, the results are generally inferior when compared to the reference method. The FreeStyle Optium Neo® glucometer obtained the best result and is therefore the best option among the glucometers evaluated; however, for the first attendance on veterinary routine, all three glucometers had a satisfactory glucose measurement until the reference method availability.

Publisher

Hindawi Limited

Subject

General Veterinary

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3