Finite Element Assessment of a Novel Patient‐Specific Mandibular Implant for Severely Atrophic Ridge

Author:

Parhiz AlirezaORCID,Nourishirazi RezaORCID,Asadi AmiraliORCID,Karimpour MoradORCID

Abstract

Purpose: Dental reconstruction for patients diagnosed with severe mandibular bone atrophy using common dental implants is a challenging process. In such cases, surgeons may encounter challenges such as insufficient available bone, soft tissue, damage to the inferior alveolar nerve, and even the risk of bone fracture. In this study, a new design concept of mandibular patient‐specific implants for severely atrophic ridges followed by finite element evaluation was presented to investigate the mechanical functionality of the concept.Method: The implant is comprised of two modular parts including an inferior border cover and a horseshoe‐shaped structure. This horseshoe segment fits into the cover and is then screwed to it using two screws on each side. A 1 mm deflection was applied to a reference point located between the two anterior posts to extract the resulting Von Mises stress distribution in each part and the reaction force on the reference point which corresponds to the chewing force that the patient must apply to deform the horseshoe. This 1 mm gap is a design consideration and critical distance that horseshoe contacts the gingiva and disturbs the alveolar nerve.Results: The results revealed that load was transmitted from the horseshoe to the cover, and there were no stress contours on the body of the mandible. However, stress concentration was observed in screw locations in the mandible, the amount of which was decreased by increasing the number of used screws. In horseshoe, stress concentration values were around 350 MPa, and the measured reaction force on the reference point was just under 200 N.Conclusion: The finite element analysis results showed that this concept would be functional as the minimum load would be transmitted to the mandibular ridge, and since the patients diagnosed with atrophic ridge are not able to apply load to an amount near 200 N, the horseshoe would not contact the gingiva. Also, it is concluded that increasing the number of bone screw fixations would decrease the risk of long‐term screw loosening.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3