1. Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013, China
Abstract
A new method for calculating the operational efficiency of a pumping station has been developed based on the integral principle and operation rules of the pump flow rate. To determine the energy saving space of a pumping system and to reflect the relationship between supply and demand, a new method for evaluating the energy consumption rate of a pump system has been developed based on the principle of an inverter-controlled water supply with varying pressures. These methods have been applied to a pump station with an apparently efficient operation. By evaluating energy consumption based on actual demand, we developed a new strategy that configures a single frequency converter with a small transitional pump and decreases the energy consumption by almost 14% with a payback time of less than three years.
Funder
National Natural Science Foundation of China
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献