Experience with Renal Autotransplantation: Typical and Atypical Indications

Author:

Bourgi Ali1ORCID,Aoun Rana1,Ayoub Elias1,Moukarzel Maroun1

Affiliation:

1. Department of Urology, Hotel-Dieu de France University Hospital, Boulevard Alfred Naccache, Achrafieh, P.O. Box 166830, Beirut, Lebanon

Abstract

Introduction and Objectives. Renal autotransplantation is a kidney-saving surgical procedure used in selected patients. The purpose of this report is to review nine typical and atypical indications for kidney autotransplantation and evaluate its effectiveness in maintaining kidney function and avoiding cancer recurrence. Materials and Methods. From 1999 till 2014, nine renal autotransplantations were performed in our center. A retrospective case review was done. Four of nine patients had a solitary functioning kidney. Typical indications for autotransplantation included extended ureteric disease in 5 patients, intrasinusal tumor on a solitary kidney in 1 patient, and renal artery aneurysm in 1 patient. Atypical indications consisted in bilateral urothelial tumors in 1 patient and interrupted live kidney transplantation in 1 patient. Mean cold ischemia time was 209 minutes. Demographic factors, indications, renal function before and after surgery, and in the long term, cancer recurrence and disease-free survival were evaluated. Results. Renal function was maintained in 8 patients during the early follow-up. No serious complications occurred in the postoperative period. Median duration of follow-up was 50 months. In 4 patients with a normal contralateral kidney, mean preoperative and at discharge creatinine clearance were 105.45 ml/min and 121.02 ml/min, respectively. Although values showed an improvement in the kidney function, the difference was not significant (p value 0.3). In the other 4 patients with a solitary kidney, mean discharge creatinine clearance was 99.24 ml/min surprisingly higher than the preoperative value 96.92 ml/min. At the last follow-up, kidney function was preserved for the two groups (normal contralateral kidney/solitary kidney) with relatively stable creatinine clearance values: 108.45 ml/min and 85.9 ml/min, respectively. No patients required secondary dialysis. Conclusion. Renal autotransplantation is a rare, safe, and effective surgical procedure for the treatment of complex urologic conditions. In some instances, it may be of great utility for kidney salvage in some carefully selected patients.

Publisher

Hindawi Limited

Subject

Urology,Obstetrics and Gynaecology

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3