Development of a Portable Respiratory Gas Analyzer for Measuring Indirect Resting Energy Expenditure (REE)

Author:

Seo Hyo-Chang1,Shin Daehyeon1,Leem Chae Hun2,Joo Segyeong1ORCID

Affiliation:

1. Department of Biomedical Engineering, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea

2. Department of Physiology, Ulsan College of Medicine, Seoul, Republic of Korea

Abstract

Objective. A rapidly growing home healthcare market has resulted in the development of many portable or wearable products. Most of these products measure, estimate, or calculate physiologic signals or parameters, such as step counts, blood pressure, or electrocardiogram. One of the most important applications in home healthcare is monitoring one’s metabolic state since the change of metabolic state could reveal minor or major changes in one’s health condition. A simple and noninvasive way to measure metabolism is through breath monitoring. With breath monitoring by breath gas analysis, two important indicators like the respiratory quotient (RQ) and resting energy exposure (REE) can be calculated. Therefore, we developed a portable respiratory gas analyzer for breath monitoring to monitor metabolic state, and the performance of the developed device was tested in a clinical trial. Approach. The subjects consisted of 40 healthy men and women. Subjects begin to measure exhalation gas using Vmax 29 for 15 minutes. After that, subjects begin to measure exhalation gas via the developed respiratory gas analyzer. Finally, the recorded data on the volume of oxygen (VO2), volume of carbon dioxide (VCO2), RQ, and REE were used to validate correlations between Vmax 29 and the developed respiratory gas analyzer. Results. The results showed that the root-mean-square errors (RMSE) values of VCO2, VO2, RQ, and REE are 0.0315, 0.0417, 0.504, and 0.127. Bland-Altman plots showed that most of the VCO2, VO2, RQ, and REE values are within 95% of the significance level. Conclusions. We have successfully developed and tested a portable respiratory gas analyzer for home healthcare. However, there are limitations of the clinical trial; the number of subjects is small in size, and the age and race of subjects are confined. The developed portable respiratory gas analyzer is a cost-efficient method for measuring metabolic state and a new application of home healthcare.

Funder

Ministry of Science, ICT and Future Planning

Publisher

Hindawi Limited

Subject

Health Informatics,Biomedical Engineering,Surgery,Biotechnology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3